首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Electrochemical behavior of the antituberculosis drug isoniazid and its square-wave adsorptive stripping voltammetric estimation in bulk form, tablets and biological fluids at a mercury electrode.
【24h】

Electrochemical behavior of the antituberculosis drug isoniazid and its square-wave adsorptive stripping voltammetric estimation in bulk form, tablets and biological fluids at a mercury electrode.

机译:抗结核药异烟肼的电化学行为及其方波,片剂和汞电极上的生物液体的方波吸附溶出伏安法估算。

获取原文
获取原文并翻译 | 示例
           

摘要

Isoniazid, pyridine-4-carboxylic acid hydrazide, is an antituberculosis-agent, which is used to prevent the development of clinical tuberculosis. A validated square-wave adsorptive cathodic stripping voltammetric procedure for the trace determination of the bulk drug at the hanging mercury drop electrode (HMDE) has been developed. Under the optimized conditions, (accumulation potential=-0.9 V, accumulation time=50-300 s, scan increment=8 mV, pulse-amplitude=25 mV, frequency=120 Hz and acetate buffer at pH 5.5) isoniazed generated two irreversible cathodic peaks. The first peak current showed a linear dependence with the drug concentration over the range 5x10(-10)-2x10(-6) M. The mean percentage recoveries, based on the average of five replicate measurements, for 7x10(-9) and 5x10(-8) M isoniazid were 97.71+/-2.93 and 99.76+/-0.77, respectively. The achieved limits of detection (LOD) and quantitation (LOQ) were 1.18x10(-10) and 3.93x10(-10) M isoniazid, respectively. The procedure was applied to the assay of the drug in tablets (Isocid and T.B. Zide), spiked human serum and urine with mean percentage recoveries of 97.81+/-1.49, 97.45+/-2.09, and 97.08+/-1.06, respectively. The limits of detection of 1.47x10(-9) and 2.4x10(-8) M, and quantitation of 4.9x10(-9) and 8x10(-8) M drug in human serum and urine, respectively, were achieved. The mean values of the various pharmackinetic parameters of isoniazid (C(max), T(max), t(1/2), AUC, and K(e)), estimated from analysis of plasma of two volunteers by means of the proposed procedure were similar to literature values.
机译:吡啶-4-羧酸酰肼异烟肼是一种抗结核药,可用于预防临床结核病的发展。已经开发出一种经过验证的方波吸附阴极溶出伏安法,用于测定悬挂式汞滴电极(HMDE)上的散装药物。在优化条件下(累积电势= -0.9 V,累积时间= 50-300 s,扫描增量= 8 mV,脉冲幅度= 25 mV,频率= 120 Hz和pH 5.5的乙酸盐缓冲液)被异烟酸化生成两个不可逆的阴极高峰。第一个峰值电流与药物浓度在5x10(-10)-2x10(-6)M范围内呈线性关系。基于五次重复测量的平均值,平均回收率百分比为7x10(-9)和5x10 (-8)异烟肼M分别为97.71 +/- 2.93和99.76 +/- 0.77。异烟肼M的检出限(LOD)和定量限(LOQ)分别为1.18x10(-10)和3.93x10(-10)。该方法用于测定片剂(Isocid和T.B. Zide),加标的人血清和尿液中药物的平均回收率分别为97.81 +/- 1.49、97.45 +/- 2.09和97.08 +/- 1.06。在人血清和尿液中分别达到了1.47x10(-9)和2.4x10(-8)M的检出限以及4.9x10(-9)和8x10(-8)M药物的定量限。异烟肼(C(max),T(max),t(1/2),AUC和K(e))的各种药理学参数平均值通过拟议中的两名志愿者的血浆分析得出程序与文献价值相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号