首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Establishment and comparison of three novel methods for the determination of the photodynamic therapy agent 2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) in human serum
【24h】

Establishment and comparison of three novel methods for the determination of the photodynamic therapy agent 2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) in human serum

机译:测定人血清中光动力治疗剂2- [1-己氧基乙基] -2-二乙烯基焦脱镁叶绿酸-a(HPPH)的三种新方法的建立和比较

获取原文
获取原文并翻译 | 示例
       

摘要

2-[1-Hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) is a second-generation photosensitizer that has been applied in clinical studies of photodynamic therapy for a variety of malignant lesions. Based on the differences in selectivity and labour intensity, three novel methods - fluorescence detection coupled with high performance liquid chromatography (LC-FLD), LC-tandem mass spectrometry (LC-MS/MS) and fluorescence-based microplate reader methods - were developed for the determination of HPPH in human serum, which allowed comparison of fluorescence and MS platform for HPPH quantification. All three methods have been validated and successfully applied to support the clinical pharmacokinetic study of HPPH. The concentrations measured by LC-FLD matched those by LC-MS/MS with a correlation coefficient (r = 0.994) and coefficient of determination (r(2) = 0.989). Data consistency was also found between the measurements of microplate reader and LC-MS/MS with a correlation coefficient (r = 0.999) and coefficient of determination (r(2) = 0.998), indicating that fluorescence assay, the low cost alternative with a relatively poorer selectivity, is clearly suitable for the quantification of HPPH. Calibration curves in the methods of LC-FLD and microplate reader were linear (r square 0.998) over the concentration range from 50 to 5000 ng/mL, and linearity was obtained over the concentration range from 5 to 1000 ng/mL in the LC-MS/MS method. Compared with the other two methods, the fluorescence-based microplate reader method with proven high selectivity should be strongly recommended because of obvious advantages such as the lowest labour intensity, the lowest instrument cost, a better sensitivity than LC-FLD and the very rapid determination of large number of samples (24 samples/40 s). (C) 2015 Elsevier B.V. All rights reserved.
机译:2- [1-己氧基氧基乙基] -2-癸基焦脱镁叶绿酸-a(HPPH)是第二代光敏剂,已被用于光动力疗法对各种恶性病变的临床研究中。根据选择性和劳动强度的差异,开发了三种新方法-荧光检测结合高效液相色谱(LC-FLD),LC串联质谱(LC-MS / MS)和基于荧光的酶标仪方法用于测定人血清中的HPPH,从而可以比较荧光和MS平台进行HPPH定量。这三种方法均已验证并成功用于支持HPPH的临床药代动力学研究。 LC-FLD测得的浓度与LC-MS / MS测得的浓度相关,相关系数(r = 0.994)和测定系数(r(2)= 0.989)。在酶标仪和LC-MS / MS的测量值之间也发现了数据一致性,相关系数(r = 0.999)和测定系数(r(2)= 0.998),表明荧光检测是一种低成本的荧光检测方法。相对较差的选择性显然适用于HPPH的定量。 LC-FLD和酶标仪的校准曲线在50至5000 ng / mL的浓度范围内呈线性(r square 0.998),在LC-FLD和酶标仪在5至1000 ng / mL的浓度范围内具有线性MS / MS方法。与其他两种方法相比,应强烈推荐使用已证明具有高选择性的基于荧光的酶标仪方法,因为它具有明显的优势,例如最低的劳动强度,最低的仪器成本,比LC-FLD更好的灵敏度以及非常快速的测定方法大量样本(24个样本/ 40 s)。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号