Precision in affinity capillary electrophoresis for drug-protein binding studies.

机译:用于药物-蛋白质结合研究的亲和毛细管电泳精度高。

获取原文
获取原文并翻译 | 示例
           

摘要

In order to achieve excellent precision in the estimation of binding constants by affinity capillary electrophoresis (ACE), electroosmotic flow (EOF) stability is the key parameter, especially when using proteins in binding assays. Appropriate rinsing protocols are mandatory. In our study, the capillary was rinsed after each run with 0.1 mol/L sodium hydroxide for 2.0 min, with water for 2.0 min followed by running electrolyte (phosphate buffer at pH 7.4) for 3.0 min (pressure=3000 mbar each). Tryptophan-human serum albumin, warfarin-bovine serum albumin and quercetin-beta-lactoglobulin were used as ACE models. Further improvements in precision have been obtained by avoiding a complete standstill of liquid within the capillary and flushing the capillary with buffer for 25 min after each 30 consecutive runs. The precision of measurements is further improved by the use of mobility ratios to report mobility changes (RSD% less than 0.5% in a long-term measurement, n=300-600). Apart from the importance of a stable EOF, other ACE key parameters include protein concentration, drug plug length, applied voltage, and the choice of the regression method. In the present work, useful protocols and templates are provided in order to allow users a quick and efficient start with ACE methods. The comprehensive experimental part can serve as a checklist, which parameters need to be addressed for successfully applying ACE. Here, the suggested experimental design allows for the determination of binding constants within a couple of hours using standard instrumentation. This time could still be decreased by orders of magnitude using capillary arrays or miniaturized systems.
机译:为了在通过亲和毛细管电泳(ACE)估算结合常数时获得出色的精度,电渗流(EOF)稳定性是关键参数,尤其是在结合测定中使用蛋白质时。必须使用适当的冲洗协议。在我们的研究中,每次运行后用0.1 mol / L氢氧化钠冲洗毛细管2.0分钟,用水冲洗2.0分钟,然后将电解液(pH 7.4的磷酸盐缓冲液)冲洗3.0分钟(每个压力= 3000 mbar)。色氨酸-人血清白蛋白,华法林-牛血清白蛋白和槲皮素-β-乳球蛋白用作ACE模型。通过避免毛细管内液体完全停滞并在每30次连续运行后用缓冲液冲洗毛细管25分钟,可以进一步提高精度。通过使用迁移率比率报告迁移率变化(长期测量中,RSD%小于0.5%,n = 300-600)可以进一步提高测量的精度。除了稳定EOF的重要性外,其他ACE关键参数还包括蛋白质浓度,药物栓塞长度,施加电压和回归方法的选择。在当前工作中,提供了有用的协议和模板,以允许用户快速有效地使用ACE方法。全面的实验部分可以用作清单,成功应用ACE需要解决哪些参数。在这里,建议的实验设计允许使用标准仪器在几个小时内确定结合常数。使用毛细管阵列或小型化系统,该时间仍可以减少几个数量级。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号