首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Measurement of ethyl methanesulfonate in human plasma and breast milk samples using high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.
【24h】

Measurement of ethyl methanesulfonate in human plasma and breast milk samples using high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

机译:使用高效液相色谱-常压化学电离-串联质谱法测定人血浆和母乳样品中的甲磺酸乙酯。

获取原文
获取原文并翻译 | 示例
       

摘要

Ethyl methanesulfonate (EMS) is a mesylate ester, which is known to be a potent mutagen, teratogen, and possibly carcinogen. Mesylate esters have been found in pharmaceuticals as contaminants formed during the manufacturing process and may potentially pose an exposure hazard to humans. We have developed and validated a method for detection of trace amounts (ng/ml levels) of EMS in human plasma and breast milk. The samples were extracted by matrix solid-phase dispersion with ethyl acetate using Hydromatrix and the ASE 200 Accelerated Solvent Extractor. The extracts were separated by high-performance liquid chromatography (HPLC) using a HILIC column. The detection was performed with a triple quadrupole mass spectrometer (TSQ Quantum Ultra, Thermo Electron Corporation) using atmospheric pressure chemical ionization in negative-ion mode and multiple reaction monitoring. The use of a surrogate internal standard in combination with HPLC-MS/MS provided a high degree of accuracy and precision. The extraction efficiency was greater than 70%. Repeated analyses of plasma and breast milk samples spiked with high (100 ng/ml), medium (50 ng/ml) and low (5 ng/ml) concentrations of the analytes gave relative standard deviations of less than 12%. The limits of detection were in the range of 0.5-0.9 ng/ml for both matrices.
机译:甲磺酸乙酯(EMS)是甲磺酸酯,已知是有效的诱变剂,致畸剂,甚至可能是致癌物。甲磺酸酯已在药物中被发现为在制造过程中形成的污染物,并可能对人体造成危害。我们已经开发并验证了一种检测人血浆和母乳中痕量(ng / ml水平)EMS的方法。使用Hydromatrix和ASE 200加速溶剂萃取器,通过使用乙酸乙酯的基质固相分散体萃取样品。使用HILIC柱,通过高效液相色谱法(HPLC)分离提取物。使用三极四极质谱仪(TSQ Quantum Ultra,Thermo Electron Corporation)进行检测,使用负离子模式下的大气压化学电离和多反应监测。将替代内标与HPLC-MS / MS结合使用可提供高度的准确性和精密度。提取效率大于70%。重复分析掺入高浓度(100 ng / ml),中等浓度(50 ng / ml)和低浓度(5 ng / ml)的血浆和母乳样品的相对标准偏差小于12%。两种基质的检出限在0.5-0.9 ng / ml范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号