首页> 外文期刊>Journal of orthopaedic trauma >Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid lockedonlocked screw configurations.
【24h】

Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid lockedonlocked screw configurations.

机译:Peri-Loc近端胫骨板的生物力学强度:全锁定与混合锁定/非锁定螺钉配置的比较。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

OBJECTIVE: The purpose of this study was to compare the biomechanical properties of a contoured locking plate instrumented with either an all-locked or hybrid lockedonlocked screw construct in a proximal metaphyseal fracture of the tibia (AO 41-A3.2). METHODS: A standardized proximal metaphyseal wedge osteotomy (AO 41-A3.2) was created in five pairs of cadaveric tibia. Each pair was randomly instrumented with either an all-locked or combination lockedonlocked screw construct using a locked contoured periarticular plate (Peri-Loc periarticular locked plating system, Smith & Nephew, Memphis, TN). Vertical subsidence (irreversible deformation) and deflection (reversible deformation) in each pair were analyzed and compared. Load to failure, defined by complete fracture gap closure, was also determined. RESULTS: There was no statistically significant difference in vertical subsidence (P = 0.19) or deflection (P = 0.19) of the proximal tibia between the all-locked and combination lockedonlocked screw construct with increasing levels of cyclical axial load from 200 to 1200 N. Failure occurred at a mean value of 2160 N in the locked group and 1760 N in the hybrid group (P = 0.19); the failure mode was plate bending in all specimens. CONCLUSIONS: The results indicate that the use of compression screws with locked screws in this particular construct allows a similar amount of irreversible and reversible deformation in response to an axial load when compared to an all-locked screw construct. This suggests that there is no statistically significant difference in the stability in fixation between the two methods, allowing the surgeon the freedom to choose the appropriate screw combination unique to each fracture.
机译:目的:本研究的目的是比较在胫骨近端干phy端骨折中,采用全锁定或混合锁定/非锁定螺钉构造的仿形锁定板的生物力学特性(AO 41-A3.2)。方法:在五对尸体胫骨中创建了标准化的近端干phy端楔形截骨术(AO 41-A3.2)。使用锁紧轮廓的关节周围板(Peri-Loc关节周围锁定板系统,Smith&Nephew,孟菲斯,田纳西州),用全锁定或组合锁定/非锁定螺钉构造随机地对每对器械进行检测。对每对中的垂直沉降(不可逆变形)和挠度(可逆变形)进行了分析和比较。还确定了通过完全闭合缝隙闭合确定的破坏载荷。结果:全锁定和组合锁定/非锁定螺钉结构之间的垂直沉降(P = 0.19)或胫骨近端挠度(P = 0.19)的统计学差异无统计学意义,其周期性轴向载荷水平从200升高至1200 N.锁定组的平均值为2160 N,混合动力组的平均值为1760 N(P = 0.19)。破坏模式是所有样品的板弯曲。结论:结果表明,与全锁定螺钉结构相比,在这种特殊结构中使用带有锁定螺钉的压缩螺钉时,由于轴向载荷,其可发生相似数量的不可逆和可逆变形。这表明这两种方法之间的固定稳定性在统计学上没有显着差异,从而使外科医生可以自由选择每种骨折特有的适当螺钉组合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号