...
首页> 外文期刊>Journal of orthopaedic trauma >Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: a biomechanical study.
【24h】

Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: a biomechanical study.

机译:三皮质螺钉固定与改良缝合线结构固定踝关节联合损伤的比较:一项生物力学研究。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: To assess the viability of using a modified flexible suture implant instead of a tricortical screw for fixation of ankle syndesmosis failures. DESIGN: Randomized biomechanical study. SETTING: Orthopaedic Research Laboratories at the University of North Carolina at Chapel Hill. INTERVENTION: Formalin-preserved cadaveric legs were used in pairs. Two holes, 2.5 millimeters in diameter and 7.0 to 10.0 millimeters apart horizontally, were drilled through the fibula and tibia 2.0 centimeters above the tibial plafond. Two strands of Number 5 suture were passed through the holes and tied. Similarly, a 3.5-millimeter tricortical screw was placed on the opposite leg of each pair at 2.0 centimeters. The ankles were tested to failure. This process was repeated at 5.0 centimeters above the tibial plafond. MAIN OUTCOME MEASUREMENTS: Maximum load and displacement at failure of the suture construct at 2.0 centimeters and at 5.0 centimeters were compared with a tricortical screw at 2.0 centimeters and at 5.0 centimeters. RESULTS: There was no significant difference in strength or displacement between the flexible suture implant and the tricortical screw at either 2.0 centimeters or 5.0 centimeters. The fixations at 5.0 centimeters had significantly increased holding strength over fixations at 2.0 centimeters, and the fixations had significantly greater displacement at 2.0 centimeters than at 5.0 centimeters. CONCLUSION: This study confirms that flexible syndesmosis repair is a viable option for internal fixation of ankle mortise instability due to syndesmosis rupture.
机译:目的:评估使用改良的柔性缝合线植入物代替三皮质螺钉固定踝关节融合失败的可行性。设计:随机生物力学研究。地点:北卡罗来纳大学教堂山分校的骨科研究实验室。干预:成对使用福尔马林保存的尸体腿。在腓骨和胫骨上方2厘米处钻两个直径2.5毫米,水平间隔7.0至10.0毫米的孔。将两股5号缝合线穿过孔并打结。同样,将3.5毫米的三皮质螺钉放置在每对相对腿上2.0厘米处。脚踝被测试到失败。在胫骨平台上方5.0厘米处重复此过程。主要观察指标:将缝合结构在2.0厘米和5.0厘米时的最大载荷和位移与在2.0厘米和5.0厘米处的三皮质螺钉进行比较。结果:在2.0厘米或5.0厘米处,柔性缝合线植入物和三皮质螺钉之间的强度或位移无明显差异。与在2.0厘米处的固定相比,在5.0厘米处的固定具有显着增加的保持强度,并且在2.0厘米处的固定比在5.0厘米处具有更大的位移。结论:这项研究证实了灵活的联合修复对于因联合破裂而导致的踝关节不稳内固定是一种可行的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号