The purpose of this study was to evaluate the colour errors of visual shade selection by five different shade guides. The maxillary left central incisors of sixty participants were visually evaluated by two groups of prosthodontists, with different clinical experience. The shade selection results were recorded and the most selected tab was determined as the resultant shade for each tooth. If totally different opinions were obtained, consensus was needed to determine the resultant shade among the observers. The colour distributions (L*, a* and b*) of each tooth and shade tab were measured using a spectroradiometer. The coverage errors (CEs) of each shade guide and colour differences (DeltaE values) between a tooth and the selected shade tabs were calculated. Two-way anova and Tukey's post hoc analysis were used to evaluate the differences of CE and DeltaE values among shade guides and clinical experience (alpha = 0.05). Coverage errors and DeltaE values in all of the five shade guide systems were all beyond the clinical threshold of 3.3 units. The consensus led to a better colour matching than that of the single decision group in Vitapan 3D-Master and Shofu NCC shade guides. A significant difference (P < 0.001) was found among DeltaE values of the shade guide system and clinical experience. In conclusion, all five of the shade guide systems used did not achieve clinically compatible shade matching. However, the Vitapan 3D Master shade guide system resulted in the lowest CEs and DeltaE values. Consensus could be helpful in enhancing the aesthetic results using Vitapan 3D Master and Shofu NCC shade guides.
机译:这项研究的目的是通过五种不同的阴影指南评估视觉阴影选择的颜色误差。由两组具有不同临床经验的修复牙齿医师对60名参与者的上颌左中切牙进行了视觉评估。记录阴影选择结果,并将选择最多的标签确定为每个牙齿的最终阴影。如果获得完全不同的意见,则需要共识来确定观察者之间的最终阴影。使用分光辐射计测量每个牙齿和阴影凸片的颜色分布(L *,a *和b *)。计算了每个阴影引导的覆盖误差(CE)以及牙齿和所选阴影选项卡之间的色差(DeltaE值)。使用双向方差分析和Tukey事后分析来评估阴影指南和临床经验之间的CE和DeltaE值的差异(α= 0.05)。在所有五个遮光罩系统中,覆盖率误差和DeltaE值均超出了3.3个单位的临床阈值。共识导致比Vitapan 3D-Master和Shofu NCC阴影指南中的单个决策组更好的色彩匹配。遮阳指南系统的DeltaE值与临床经验之间存在显着差异(P <0.001)。总之,所使用的所有五种阴影引导系统均未实现临床兼容的阴影匹配。但是,Vitapan 3D Master阴影引导系统导致最低的CE和DeltaE值。使用Vitapan 3D Master和Shofu NCC阴影辅助线,共识有助于增强美学效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号