首页> 外文期刊>Journal of orthopaedic trauma >Operative treatment of displaced intra-articular fractures of the calcaneus using absorbable internal fixation: a prospective study of twenty-five fractures.
【24h】

Operative treatment of displaced intra-articular fractures of the calcaneus using absorbable internal fixation: a prospective study of twenty-five fractures.

机译:可吸收内固定术治疗跟骨关节内移位的骨折:前瞻性研究二十五个骨折。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To document the use of absorbable implants in the operative treatment of displaced intra-articular fractures of the calcaneus. DESIGN: Prospective clinical study. SETTING: Level one trauma center, university hospital. PATIENTS: Twenty-five displaced intra-articular calcaneal fractures in twenty-one patients. INTERVENTION: The fractures were reduced operatively and fixed with absorbable self-reinforced polyglycolide rods. MAIN OUTCOME MEASUREMENTS: Reduction, healing, and stability of fixation were assessed on radiographs. The functional result was scored using the method of Crosby and Fitzgibbons. Patient satisfaction was recorded. RESULTS: The mean Bohler angle was -12 degrees (standard deviation 22 degrees) preoperatively and 20 degrees (standard deviation 13 degrees) postoperatively. After a two-year follow-up, seven patients had excellent, five good, three fair, and six poor functional results. Subjectively, fifteen patients were satisfied and six were dissatisfied. Twelve patients returned to work within one year, three were unemployed, two were retired prior to the accident, and four were unable to work because of the calcaneal fracture. The postoperative Bohler angle and later the appearance or absence of posttraumatic subtalar arthritis were significant prognostic factors. CONCLUSIONS: Results with absorbable implants are similar to those with other operative methods. Advantages include the absence of secondary procedures for implant removal and undisturbed computed tomography scans postoperatively.
机译:目的:记录可吸收植入物在手术治疗跟骨关节内移位骨折中的应用。设计:前瞻性临床研究。地点:大学医院一级创伤中心。患者:21例患者中有25例关节内跟骨骨折。干预:通过可吸收的自增强聚乙交酯棒对骨折进行手术复位并固定。主要观察指标:在X光片上评估复位,复位和固定稳定性。使用Crosby和Fitzgibbons的方法对功能结果进行评分。记录患者满意度。结果:术前平均布勒角为-12度(标准偏差22度),术后为20度(标准偏差13度)。经过两年的随访,有7例患者具有良好的功能,5例良好,3例正常和6例功能不良。主观上,15例患者满意,6例不满意。一年内有十二名患者重返工作岗位,三名失业,两人在事故发生之前退休,四名因跟骨骨折而无法工作。术后Bohler角以及创伤后距下关节炎的出现或不存在是重要的预后因素。结论:可吸收植入物的结果与其他手术方法相似。优点包括无需二次手术即可去除植入物,且术后无需进行计算机断层扫描。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号