BACKGROUND: The joint gap is set rectangular at 90 degrees flexion during total knee arthroplasty (TKA). However, the condition of the joint gap in deep knee flexion is obscure. METHODS: The method for obtaining a posteroanterior view radiograph of the knee at 90 degrees flexion (the epicondylar view) was modified, and a method to obtain an anteroposterior view radiograph at 120 degrees flexion (deep flexion view) was established. With this method, subjects lie on the radiography table with their thighs placed on a device so their lower legs hang down in neutral rotation with a 1.5-kg weight attached to the ankle. The joint gap angle and medial and lateral joint space widths were measured on epicondylar view and deep flexion view radiographs in 20 normal male subjects, 20 normal female subjects, and 20 subjects after TKA. RESULTS: The joint gap was almost rectangular at two flexion angles in normal subjects. In the implanted knees, the gap angle was 1.4 degrees varus +/- 3.3 degrees (mean +/- standard deviation), and no significant difference was found between medial and lateral joint space widths at 90 degrees flexion. In contrast, the gap angle was 2.5 degrees varus +/- 2.5 degrees and the lateral joint space width was significantly wider than the medial joint space width at 120 degrees flexion (P < 0.001). The gap angle was more varus with a significant difference in the implanted knees than that in the normal subjects at 120 degrees flexion (P < 0.001). CONCLUSIONS: The joint gap was trapezoidal with a wider lateral side at 120 degrees flexion even though it was almost rectangular at 90 degrees flexion after TKA.
机译:背景:在全膝关节置换术(TKA)期间,将关节间隙设置为90度弯曲的矩形。然而,膝深屈关节关节间隙的情况是模糊的。方法:修改了获得90度屈曲膝关节后前位X线片(con上位)的方法,建立了获得120度屈曲膝位后侧位X线片(深位屈曲)的方法。通过这种方法,受试者躺在大腿上的X光检查台上,使大腿放在设备上,使其小腿以中性旋转垂下,并在踝关节上附着1.5公斤重的重量。在20例正常男性受试者,20例正常女性受试者和TKA后20例受试者的epi上和深屈曲X线照片上测量关节间隙角度以及内侧和外侧关节间隙宽度。结果:正常受试者在两个屈曲角度下关节间隙几乎为矩形。在植入的膝盖中,间隙角为1.4度内翻+/- 3.3度(平均+/-标准偏差),屈曲90度时内侧和外侧关节间隙宽度之间没有发现显着差异。相反,在120度屈曲时,间隙角为2.5度内翻+/- 2.5度,外侧关节间隙宽度明显大于内侧关节间隙宽度(P <0.001)。与正常受试者在120度屈曲时相比,间隙角内翻角度更大,在植入的膝盖中差异显着(P <0.001)。结论:关节间隙为梯形,在屈曲120度时其侧面较宽,即使在TKA后屈曲90度时几乎为矩形。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号