Evaluation of cervical range of motion and isometric neck muscle strength: reliability and validity.

机译:颈椎活动范围和等距颈肌力量的评估:可靠性和有效性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To examine the test-retest reliability and construct validity of cervical active range of motion and isometric neck muscle strength as measured by the Multi Cervical Rehabilitation Unit (Hanoun Medical Inc., Ontario). DESIGN: A cross-sectional study. SETTING: Institutional practice. SUBJECTS: Twenty-one patients with neck pain and 25 healthy volunteers. METHODS: After a trial-run session, active range of motion (AROM) was measured in the subsequent two sessions, with 2-3 days in between. During each session, three measurements were taken for each direction (flexion, extension, lateral flexions and rotations). The measurement of isometric strength was after a 15-minute break following completion of the measurement of AROM. Three measurements were made for each of the six directions (flexion, extension, lateral flexions, protraction and retraction). The software of the Multi Cervical Rehabilitation Unit automatically recorded and calculated the maximum AROM and isometric strength. RESULTS: There was a good to high level of reliability in the measurement of AROM for both groups of subjects, with intraclass correlation coefficients (ICCs) ranging from 0.81 to 0.96. Results also demonstrated very good to excellent reliability in isometric strength measurement (ICCs ranged from 0.92 to 0.99). Moreover, there was a significant difference in isometric neck muscle strength (p = 0.001) and in AROM (p = 0.034) between the two groups. CONCLUSIONS: The Multi Cervical Rehabilitation Unit was found to be reliable and valid for testing the cervical active range of motion and isometric neck muscle strength for both normal and patient subjects.
机译:目的:检查多颈椎康复单元(安大略省哈农医疗公司)测量的颈项活动范围和等距颈肌力量的重测信度和结构效度。设计:横断面研究。地点:机构实践。受试者:21名颈部疼痛患者和25名健康志愿者。方法:在试运行会议之后,在随后的两个会议中测量了主动运动范围(AROM),中间间隔2-3天。在每个阶段中,对每个方向(弯曲,伸展,横向弯曲和旋转)进行了三个测量。等距强度的测量是在完成AROM的测量之后15分钟的休息之后进行的。对六个方向(屈曲,伸展,横向屈曲,伸出和缩回)分别进行了三个测量。多颈椎康复单元的软件会自动记录并计算最大AROM和等轴测强度。结果:两组受试者的AROM测量均具有良好至高度的可靠性,组内相关系数(ICC)为0.81至0.96。结果还表明,在等距强度测量中,ICC的可靠性非常好至极好(ICC范围为0.92至0.99)。此外,两组之间的等轴颈肌力量(p = 0.001)和AROM(p = 0.034)有显着差异。结论:多颈椎康复单元被发现对于测试正常和患者受试者的颈椎活动范围和等轴测颈肌力量是可靠且有效的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号