Functional stereotactic radiosurgery involving a dedicated linear accelerator and gamma unit: a comparison study.

机译:涉及专用线性加速器和伽马单元的功能性立体定向放射外科手术:一项比较研究。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECT: The purpose of this work was to investigate the targeting and dosimetric characteristics of a linear accelerator (LINAC) system dedicated for stereotactic radiosurgery compared with those of a commercial gamma knife (GK) unit. METHODS: A phantom was rigidly affixed within a Leksell stereotactic frame and axial computerized tomography scans were obtained using an appropriate stereotactic localization device. Treatment plans were performed, film was inserted into a recessed area, and the phantom was positioned and treated according to each treatment plan. In the case of the LINAC system, four 140 degrees arcs, spanning +/-60 degrees of couch rotation, were used. In the case of the GK unit, all 201 sources were left unplugged. Radiation was delivered using 3- and 8-mm LINAC collimators and 4- and 8-mm collimators of the GK unit. Targeting ability was investigated independently on the dedicated LINAC by using a primate model. Measured 50% spot widths for multisource, single-shot radiation exceeded nominal values in all cases by 38 to 70% for the GK unit and 11 to 33% for the LINAC system. Measured offsets were indicative of submillimeter targeting precision on both devices. In primate studies, the appearance of an magnetic resonance imaging-enhancing lesion coincided with the intended target. CONCLUSIONS: Radiosurgery performed using the 3-mm collimator of the dedicated LINAC exhibited characteristics that compared favorably with those of a dedicated GK unit. Overall targeting accuracy in the submillimeter range can be achieved, and dose distributions with sharp falloff can be expected for both devices.
机译:目的:这项工作的目的是研究专用于立体定向放射外科的线性加速器(LINAC)系统与商用伽玛刀(GK)单元相比的瞄准和剂量特性。方法:将幻像牢固地固定在Leksell立体定位框架内,并使用适当的立体定位装置获得轴向计算机断层扫描。执行治疗计划,将胶卷插入凹陷区域,并根据每个治疗计划放置并处理体模。在LINAC系统的情况下,使用了四个140度弧度,横跨了+/- 60度的沙发旋转角度。对于GK单元,所有201个信号源均未拔出。使用GK单元的3毫米和8毫米LINAC准直器以及4毫米和8毫米准直器进行辐射。使用灵长类动物模型在专用LINAC上独立研究了靶向能力。在所有情况下,测量到的多源单发辐射的50%点宽在所有情况下均超过标称值,GK装置超过38%至70%,LINAC系统超过11%至33%。测得的偏移量表示这两种设备的亚毫米瞄准精度。在灵长类动物研究中,磁共振成像增强病变的出现与预期目标一致。结论:使用专用LINAC的3毫米准直仪进行的放射外科手术具有与专用GK单元相比优越的特性。可以实现亚毫米范围内的总体瞄准精度,并且两种设备的剂量分布均会急剧下降。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号