首页> 外文期刊>Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology >Yield of a novel ultra-low-dose computed tomography device mounted on a dedicated cardiac SPECT system in improving the accuracy of myocardial perfusion imaging and the detection of chest abnormalities.
【24h】

Yield of a novel ultra-low-dose computed tomography device mounted on a dedicated cardiac SPECT system in improving the accuracy of myocardial perfusion imaging and the detection of chest abnormalities.

机译:安装在专用心脏SPECT系统上的新型超低剂量计算机断层扫描设备的产量,可提高心肌灌注成像的准确性和检测胸部异常。

获取原文
获取原文并翻译 | 示例
           

摘要

To examine the yield of an ultra-low-dose computed tomography (CT) transmission module for attenuation-correction (AC) on a dedicated cardiac camera in evaluation of SPECT-myocardial perfusion imaging (MPI) in the diagnosis of CAD and for additional chest abnormalities.The study group included 150 patients with known or suspected CAD referred for technetium sestamibi SPECT MPI. CT transmission scanning (effective radiation 0.17 mSv) was performed after each gated SPECT scan. AC and non-corrected (NC) SPECT scans were evaluated on a 5-point scale using a 17-segment model, and the sum stress score (SSS) and sum rest score (SRS) were calculated for each condition. Overall image quality, sensitivity and normalcy rate (51 patients) and processing of 28 CT slices were screened for chest findings.CT-based AC significantly improved image quality (P = .01). Mean SSS was 3.8 ± 5.8 with AC and 6.1 ± 7.1 with NC (P < .001); the respective SRS values were 2.6 ± 6.3 and 3.9 ± 7.7 (P < .001). The sensitivity of detecting ≥70% stenosis was 71% and 86% (P = NS) and the normalcy rate was 30% and 89% (P < .0001) in NC and AC SPECT MPI, respectively. Chest CT: lung abnormalities in 31%, aortic calcifications in 27%, and hiatus hernia in 5%.Ultra-low-dose CT for AC of SPECT-MPI improves image quality, diagnostic accuracy and suggests detection of chest findings.
机译:要检查用于专用心脏相机的衰减校正(AC)的超低剂量计算机断层扫描(CT)传输模块的产量,以评估SPECT-心肌灌注成像(MPI)在诊断CAD和其他胸部疾病方面的价值研究组包括150名已知或疑似CAD的患者,这些患者因sestamibi SPECT MPI而被转诊。每次门控SPECT扫描后均进行CT透射扫描(有效辐射0.17 mSv)。使用17段模型以5分制对AC和未校正(NC)SPECT扫描进行评估,并针对每种情况计算总压力得分(SSS)和总静止得分(SRS)。筛查整体影像质量,敏感性和正常率(51例患者)以及处理28枚CT切片的胸部影像。基于CT的AC显着改善影像质量(P = 0.01)。 AC的平均SSS为3.8±5.8,NC的平均SSS为6.1±7.1(P <.001);各自的SRS值分别为2.6±6.3和3.9±7.7(P <.001)。在NC和AC SPECT MPI中,检测≥70%狭窄的敏感性分别为71%和86%(P = NS),正常率分别为30%和89%(P <.0001)。胸部CT:31%的肺部异常,27%的主动脉钙化和5%的裂孔疝.SPECT-MPI的AC超低剂量CT可以改善图像质量,诊断准确性并建议检测胸部发现。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号