...
首页> 外文期刊>Journal of nuclear cardiology: official publication of the American Society of Nuclear Cardiology >Myocardial perfusion imaging with real-time respiratory triggering: impact of inspiration breath-hold on left ventricular functional parameters.
【24h】

Myocardial perfusion imaging with real-time respiratory triggering: impact of inspiration breath-hold on left ventricular functional parameters.

机译:带有实时呼吸触发的心肌灌注成像:吸气屏气对左心室功能参数的影响。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: The latest gamma-camera generation with cadmium-zinc-telluride (CZT) detectors allows myocardial perfusion imaging (MPI) with respiratory triggering at breath-hold. We assessed its impact on functional left ventricular (LV) parameters. METHODS: Twenty-eight consecutive patients underwent a one-day (99m)Tc-tetrofosmin pharmacologic stress/rest imaging protocol on a novel CZT camera. Electrocardiogram-gated high-dose (rest) MPI was performed without and with real-time respiratory triggering by intermittent scanning confined to breath-hold at deep inspiration. We studied the effect of respiratory triggering at deep inspiration levels on LV wall motion, wall thickening, LV volumes and ejection fraction (LVEF) compared to regular MPI without respiratory triggering. RESULTS: Compared to regular MPI without respiratory triggering, systolic and diastolic LV volumes and stroke volumes decreased significantly (P < 0.05) when respiratory triggering was applied. By contrast, there was no significant change in LVEF, with a high correlation (r = .939, P < 0.001) between the two measurements. Furthermore, respiratory triggering introduced a significant change (P < 0.05) in regional LV wall motion. CONCLUSIONS: Respiratory-triggered MPI with breath-hold at deep inspiration levels introduces significant changes to the measured LV volumes, stroke volumes and regional wall motion but does not significantly affect global LVEF when compared to regular MPI with normal breathing.
机译:背景:最新一代的伽马相机具有镉锌碲化物(CZT)检测器,可进行心肌灌注成像(MPI),并在屏气时触发呼吸。我们评估了其对功能性左心室(LV)参数的影响。方法:连续28例患者在新型CZT摄像机上接受了为期一天(99m)的Tc-四磷酸fosmin药理应激/静息成像方案。心电图门控的大剂量(静息)MPI在不进行或具有实时呼吸触发的情况下进行,通过间歇扫描限制在深吸气时屏住呼吸。与没有呼吸触发的常规MPI相比,我们研究了深部吸气水平下呼吸触发对左室壁运动,壁增厚,左室容量和射血分数(LVEF)的影响。结果:与没有呼吸触发的常规MPI相比,应用呼吸触发时收缩压和舒张压的LV量和中风量显着降低(P <0.05)。相比之下,LVEF没有显着变化,两次测量之间具有高度相关性(r = .939,P <0.001)。此外,呼吸触发引起了局部左室壁运动的显着变化(P <0.05)。结论:在深吸气水平屏住呼吸的MPI,与正常呼吸的常规MPI相比,对所测得的LV量,中风量和区域壁运动有显着变化,但对整体LVEF的影响不明显。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号