首页> 外文期刊>Journal of Microscopy >Stereological measures of trabecular bone structure: comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies.
【24h】

Stereological measures of trabecular bone structure: comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies.

机译:小梁骨结构的立体测量:人体近端胫骨活检中3D显微计算机断层扫描与2D组织学切片的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

Summary Stereology applied on histological sections is the 'gold standard' for obtaining quantitative information on cancellous bone structure. Recent advances in micro computed tomography (microCT) have made it possible to acquire three-dimensional (3D) data non-destructively. However, before the 3D methods can be used as a substitute for the current 'gold standard' they have to be verified against the existing standard. The aim of this study was to compare bone structural measures obtained from 3D microCT data sets with those obtained by stereology performed on conventional histological sections using human tibial bone biopsies. Furthermore, this study forms the first step in introducing the proximal tibia as a potential bone examination location by peripheral quantitative CT and CT. Twenty-nine trabecular bone biopsies were obtained from autopsy material at the medial side of the proximal tibial metaphysis. The biopsies were embedded in methylmetacrylate before microCT scanning in a Scanco microCT 40 scanner at a resolution of 20 x 20 x 20 microm(3), and the 3D data sets were analysed with a computer program. After microCT scanning, 16 sections were cut from the central 2 mm of each biopsy and analysed with a computerized method. Trabecular bone volume (BV/TV) and connectivity density (CD) were estimated in both modalities, whereas trabecular bone pattern factor (TBPf) was estimated on the histological sections only. Trabecular thickness (Tb.Th), number (Tb.N) and separation (Tb.Sp), and structure model index (SMI) were estimated with the microCT method only. Excellent correlations were found between the two techniques for BV/TV (r = 0.95) and CD (r = 0.95). Additionally, an excellent relationship (r = 0.95) was ascertained between TBPf and SMI. The study revealed high correlations between measures of bone structure obtained from conventional 2D sections and 3D microCT data. This indicates that 3D microCT data sets can be used as a substitute for conventional histological sections for bone structural evaluations.
机译:小结组织学切片上应用的立体学是获得有关松质骨结构定量信息的“金标准”。微型计算机断层摄影(microCT)的最新进展使得无损获取三维(3D)数据成为可能。但是,在将3D方法用作当前“黄金标准”的替代方法之前,必须先对现有标准进行验证。这项研究的目的是比较从3D microCT数据集获得的骨骼结构测量结果与通过使用人类胫骨骨活检对常规组织学切片进行的立体测量获得的结果。此外,这项研究形成了通过周围定量CT和CT引入胫骨近端作为潜在的骨检查部位的第一步。从胫骨近端干physi端内侧的尸检材料中获得了29个小梁骨活检。在用Scanco microCT 40扫描仪以20 x 20 x 20 microm(3)的分辨率进行microCT扫描之前,将活检组织嵌入甲基丙烯酸甲酯中,并使用计算机程序分析3D数据集。经过microCT扫描后,从每次活检的中心2毫米处切下16个切片,并用计算机化方法进行分析。两种方式均估计了小梁骨体积(BV / TV)和连接密度(CD),而仅在组织学切片上估计了小梁骨骨形态因子(TBPf)。仅使用microCT方法估算骨小梁厚度(Tb.Th),数量(Tb.N)和分离度(Tb.Sp)以及结构模型指数(SMI)。在BV / TV(r = 0.95)和CD(r = 0.95)的两种技术之间发现了极好的相关性。另外,在TBPf和SMI之间确定了极好​​的关系(r = 0.95)。该研究揭示了从常规2D切片获得的骨结构测量结果与3D microCT数据之间的高度相关性。这表明3D microCT数据集可以替代常规组织学切片以进行骨结构评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号