An experimental study was performed to investigate the heat transfer characteristics of the non-boiling annular two-phase flow of nitrogen gas and subcooled water through a small vertical heated tube with uniform wall heat flux. The experimental results were compared with the numerical calculations based on the two-phase flow boundary layer model. The experimental data show that the annular two-phase flow of nitrogen gas and subcooled water in a small vertical tube can provide quite high heat transfer ability, while wall temperatures lie in a low range even if at quite high wall heat fluxes. In particular, the highest values of the wall temperatures are insensitive to the change of flowing and heating conditions. This characteristic is quite suitable for highly effective cooling of polymer electrolyte membrane fuel cells.
机译:进行实验研究以研究氮气和过冷水通过均匀壁热通量小的垂直加热管的非沸腾环形两相流的传热特性。将实验结果与基于两相流边界层模型的数值计算进行了比较。实验数据表明,在较小的垂直管中,氮气和过冷水的环形两相流可提供相当高的传热能力,而即使壁热通量很高,壁温也处于较低范围内。特别地,壁温的最高值对流动和加热条件的变化不敏感。该特性非常适用于聚合物电解质膜燃料电池的高效冷却。