An ascorbate oxidase (EC 1.10.3.3) purified from Lagenaria siceraria fruit was immobilized onto egg shell membrane through glutaraldehyde coupling with 73.3% retention of its initial activity and a conjugation yield of 0.097 mg/cm2. The membrane consisting of ascorbate oxidase was mounted over an Au electrode to construct a working electrode for ascorbate biosensor. The biosensor showed optimum response i.e. current in mA within 10s at pH 6.0, 40°C and 0.6V using Ag/AgCl reference and Cu wire as auxiliary electrode. There was a linear relationship between L-ascorbic acid concentration in the range 1 x 10~(-5) M and 4 x 10~(-4) M and current. The biosensor was employed for determination of 1- ascorbic acid in serum, fruit juices and vitamin C tablets. The analytical recovery of added ascorbate in sera was 98.2% and 96.7%. Within batch and between batch coefficients of variations (CV) in ascorbate of sera were <3.6% and <4.49% respectively. L-Ascorbate values obtained for fruit juices and vitamin C tablets by present method and by DCPIP (2,6-dichlorophenolindophenol) method, showed a good correlation (r=0.993). The biosensor has advantages such as fast response time (10s), good repeatability (200 assays) and long-term stability (50% of its initial sensitivity after 4 months of storage).
机译:从戊二醛果实中纯化的抗坏血酸氧化酶(EC 1.10.3.3)通过戊二醛偶联固定在蛋壳膜上,其初始活性保留73.3%,结合产率为0.097 mg / cm2。将由抗坏血酸氧化酶组成的膜安装在Au电极上,以构建用于抗坏血酸生物传感器的工作电极。使用Ag / AgCl参比和铜线作为辅助电极,该生物传感器显示出最佳响应,即在pH 6.0、40°C和0.6V下10s内以mA为单位的电流。 L-抗坏血酸浓度在1 x 10〜(-5)M和4 x 10〜(-4)M之间与电流呈线性关系。该生物传感器用于测定血清,果汁和维生素C片剂中的1-抗坏血酸。血清中添加的抗坏血酸的分析回收率分别为98.2%和96.7%。批内和批间血清抗坏血酸的变异系数(CV)分别为<3.6%和<4.49%。通过本方法和通过DCPIP(2,6-二氯苯酚吲哚酚)方法获得的果汁和维生素C片剂的L-抗坏血酸值显示出良好的相关性(r = 0.993)。该生物传感器具有诸如快速响应时间(10秒),良好的重复性(200次测定)和长期稳定性(在存储4个月后其初始灵敏度的50%)等优点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号