OBJECTIVES: To evaluate the effect of maximum bite force (mBF) on marginal bone loss (MBL) around mini-implants in edentulous patients wearing mandibular overdentures with two retention systems: ball and bar. MATERIAL AND METHODS: Forty-five totally edentulous patients were selected from a public health center. All of them received two mini-implants (1.8 x 15 mm; Sendax) in the anterior mandible using a minimally invasive technique. A single randomization was performed to allocate the patients in two groups. Group I (n=22) received two single ball-type mini-implants and Group II (n=23) received two mini-implants splinted with a prefabricated bar. The mBF was recorded using a press-sensitive sheet Dental Prescale (Fuji) and MBL using standardized radiographs of each mini-implant at the baseline and 5, 7, 10, and 15 months after surgery; the values were compared between groups. RESULTS: Two members of Group I failed to complete the study, decreasing the number of participants to 20. There was no relationship between the mBF and the MBL of the mini-implants (Spearman's rhor(s)=0.147; P=0.378). At the 15-month follow-up, the average mBF for Group I (ball) was 247.53 +/- 132.91 N and that of Group II (bar) only 203.23 +/- 76.85 N (Mann-Whitney test; P=0.586). The MBL values were also higher for Group I (1.40 +/- 1.02 mm) than Group II (0.84 +/- 0.66 mm) during the entire 15-month follow-up period (Mann-Whitney test; P=0.077). CONCLUSIONS: No relationship was found between mBF and MBL for patients wearing overdentures retained on mini-implants using bar or ball attachment systems.
机译:目的:评估最大咬合力(mBF)对戴着下颌假牙并带有两个固定系统的无牙患者微型球周围微型骨周围骨丢失(MBL)的影响。材料与方法:从公共卫生中心选择了45名完全无牙的患者。他们都使用微创技术在前下颌骨中植入了两个微型植入物(1.8 x 15 mm; Sendax)。进行一次随机分组以将患者分为两组。第一组(n = 22)接受了两个单球型微型植入物,第二组(n = 23)接受了两个用预制棒夹板的微型植入物。使用压敏片Dental Prescale(Fuji)和MBL在基线以及手术后5、7、10和15个月时对每个微型植入物的标准化X光片记录mBF。比较各组之间的值。结果:第一组的两名成员未能完成研究,将参与者人数减少至20。微型植入物的mBF与MBL之间没有关系(Spearman的rhor(s)= 0.147; P = 0.378)。在15个月的随访中,I组(球)的平均mBF为247.53 +/- 132.91 N,II组(巴)的平均mBF仅203.23 +/- 76.85 N(Mann-Whitney检验; P = 0.586) 。在整个15个月的随访期间(Mann-Whitney测试; P = 0.077),I组的MBL值(1.40 +/- 1.02 mm)也高于II组的(0.84 +/- 0.66 mm)。结论:对于使用棒或球附着系统保留在微型植入物上的覆盖义齿的患者,mBF和MBL之间没有关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号