首页> 外文期刊>Journal of neuro-oncology. >Simultaneous integrated boost technique by helical tomotherapy for the treatment of glioblastoma multiforme with (11)C-methionine PET: report of three cases.
【24h】

Simultaneous integrated boost technique by helical tomotherapy for the treatment of glioblastoma multiforme with (11)C-methionine PET: report of three cases.

机译:(11)C-甲硫氨酸PET同时应用螺旋层析联合增强疗法治疗多形性胶质母细胞瘤:3例报道。

获取原文
获取原文并翻译 | 示例
           

摘要

We performed hypofractionated high-dose irradiation of a patient's residual glioblastoma multiforme using a simultaneous integrated boost (SIB) technique with helical tomotherapy system (HT) planning. The gross tumor volume (GTV)-1 was defined as the area of intensive (11)C-methionine (MET) uptake and GTV-2 was defined as the area of moderate MET uptake. The planning target volume (PTV)-1 encompassed GTV-1 plus a 5 mm margin, and PTV-2 encompassed GTV-2 plus a 2 mm margin. SIB with HT was performed in eight fractions, planning the dose for GTV-1 at 68 Gy (biologically effective dose: BED = 126 Gy), PTV-1 at 56 Gy (BED = 95 Gy), and PTV-2 at 40 Gy (BED = 60 Gy). In each of the target areas, the uptake value on (11)C-methionine positron emission tomography (MET-PET) was considerably decreased following SIB, although no remarkable changes were demonstrated on magnetic resonance imaging (MRI). These cases demonstrate that SIB with HT planning using MET-PET offers excellent target coverage and uniformity. In addition, SIB with HT planning using MET-PET is organ sparing and MET-PET has great efficacy for monitoring treatment response after SIB. To more clearly define the impact of SIB with HT planning using MET-PET, further investigations are required.
机译:我们使用同时​​集成增强(SIB)技术和螺旋断层扫描系统(HT)计划对患者残留的多形胶质母细胞瘤进行了大剂量放射。总肿瘤体积(GTV)-1定义为密集(11)C-蛋氨酸(MET)摄取的面积,而GTV-2定义为中度MET摄取的面积。规划目标体积(PTV)-1包含GTV-1加上5毫米的空白,PTV-2包含GTV-2加上2毫米的空白。进行HT的SIB分八部分进行,计划GTV-1的剂量为68 Gy(生物学有效剂量:BED = 126 Gy),PTV-1的剂量为56 Gy(BED = 95 Gy)和PTV-2的剂量为40 Gy (BED = 60 Gy)。在每个目标区域中,SIB后(11)C-蛋氨酸正电子发射断层显像(MET-PET)的吸收值均显着降低,尽管在磁共振成像(MRI)上未见明显变化。这些案例表明,采用MET-PET进行HT计划的SIB具有出色的目标覆盖范围和均匀性。另外,使用MET-PET进行HT计划的SIB可以节省器官,而MET-PET在监测SIB后的治疗反应方面具有很大的功效。为了使用MET-PET通过HT计划更清楚地定义SIB的影响,需要进一步的研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号