首页> 外文期刊>Clinical oral implants research >Oral rehabilitation using Camlog screw-cylinder implants with a particle-blasted and acid-etched microstructured surface. Results from a prospective study with special consideration of short implants.
【24h】

Oral rehabilitation using Camlog screw-cylinder implants with a particle-blasted and acid-etched microstructured surface. Results from a prospective study with special consideration of short implants.

机译:使用Camlog螺旋圆柱体植入物进行口腔修复,该植入物具有喷砂和酸蚀的微结构表面。前瞻性研究的结果,特别考虑了短种植体。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVES: The purpose of the present clinical study was to report on the clinical performance of screw-cylinder implants with special consideration of the survival rate of short implants. MATERIAL AND METHODS: In this prospective study with consecutive patient recruitment, Camlog screw-cylinder implants with a particle-blasted and acid-etched microstructured surface and a triple-cam tube-in-tube implant-abutment connection have been used only. Two groups of implants were evaluated: implants of 9 and 11 mm in length were considered short, those of 13 and 16 mm were considered long. Besides clinical and radiographic parameters, data of complications, patients' subjective evaluation of treatment outcome, general medical history and smoking habits were recorded. RESULTS: Three hundred and thirty-three Camlog screw-cylinder implants were inserted in 133 patients. One hundred and twenty-nine patients were available for follow-up, representing 325 implants. The median observation period was 33 months (Q(25%) 26; Q(75%) 38). After a maximum observation period of 55 months, the Kaplan-Meier-survival analysis revealed no significant difference between the mean survival probabilities of 98.3% (n=59, patient-related) of short implants, and of 95.7% of long implants (n=70, patient-related) (P=0.162). No significant difference was found between implant survival rates considering maxilla (98.7%) and mandible (98.2%). A stratified analysis of short implants revealed a significant influence of premature cover screw exposures (P=0.02) and smoking (P=0.008) on implant survival. These influences were not found significant for long implants. CONCLUSIONS: The prognosis of short Camlog implants is comparable with that of long implants. Therefore, their clinical use instead of performance of sophisticated vertical augmentation procedures before installation of long implants might be considered as alternative treatment option. In smokers, the use of short implants should be considered cautiously, however. The risk of premature cover screw exposure should be minimized.
机译:目的:本临床研究的目的是报告螺柱式植入物的临床性能,并特别考虑短植入物的存活率。材料与方法:在这项连续招募患者的前瞻性研究中,仅使用了具有loglog-blasted和酸蚀的微结构表面以及三凸轮管套管式种植体-基台连接的Camlog螺杆式种植体。评价了两组植入物:长度为9和11毫米的植入物被认为是短的,长度为13和16毫米的植入物被认为是长的。除临床和放射学参数外,还记录并发症数据,患者对治疗结果的主观评价,一般病史和吸烟习惯。结果:133例患者中共插入了33个Camlog螺钉圆柱体植入物。 129位患者可供随访,代表325个植入物。中位观察期为33个月(Q(25%)26; Q(75%)38)。在最长观察期55个月后,Kaplan-Meier生存分析显示,短植入物的98.3%(n = 59,与患者相关)的平均生存概率与长植入物(n。 = 70,与患者相关)(P = 0.162)。在考虑上颌骨(98.7%)和下颌骨(98.2%)的种植体存活率之间没有发现显着差异。对短植入物的分层分析显示,过早的覆盖螺钉暴露量(P = 0.02)和吸烟(P = 0.008)对植入物存活率有显着影响。这些影响对于长植入物没有显着影响。结论:Camlog短种植体的预后与长种植体的预后相当。因此,在安装长植入物之前,将其临床使用而不是复杂的垂直增强手术的性能视为替代治疗选择。但是,在吸烟者中,应谨慎考虑使用短植入物。盖螺丝过早暴露的风险应降至最低。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号