首页> 外文期刊>Clinical oral implants research >Osseointegration and stability of a modified sand-blasted acid-etched implant: an experimental pilot study in sheep
【24h】

Osseointegration and stability of a modified sand-blasted acid-etched implant: an experimental pilot study in sheep

机译:改良的喷砂酸蚀植入物的骨整合和稳定性:在绵羊中的实验性试验研究

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: The aim of this pilot study was to compare the early-term osseointegration characteristics of standard (SLA) and modified sand-blasted and acid-etched (modSLA) implants in an experimental animal model. Material and methods: A total of 30 SLA and modSLA implants were placed to the tibiae of three sheep and the insertion torque value (ITV) and resonance frequency analysis (RFA) measurements were performed. RFA measurement was repeated on 3 and 6 weeks healed implants after which the animals were sacrificed for histomorphometric analysis. Bone-to-implant contact was assessed on the non-decalcified sections. Six weeks healed implants were also subjected to the reverse torque test (RTT). Results were analyzed by the Friedman test, Kruskal-Wallis test and Spearman rank correlation test. Results: All implants reached to a strong primary stability with a mean 36.13 + 2.47 and 35.47 +- 2.85 N/cm ITV. In the surgical stage, RFA values for SLA and modSLA implants were found to be 72.27 +- 3.17 and 71.6 +- 2.87, respectively. After 3 weeks of healing, mean BIC% (80.64 +- 13.89%) and RFA value (76.8 +- 1.14) of modSLA implants were significantly higher (P = 0.0002) than that of SLA implants (64.39 +- 21.2 BIC% and 74.2 +- 4.76 RFA). However, no statistically significant difference between SLA and modSLA implants was recorded after 6 weeks of healing. Both implants reveaied similar results in the RTT test (115.2 +- 4.14 and 117 +- 4.47 N/cm for SLA and modSLA implants, respectively). No correlation was found between RFA and BIC%. Conclusion: Within the limits of this pilot study, it can be concluded that modSLA implants achieve a higher bone contact and stability at earlier time points when compared with SLA implants.
机译:目的:本实验研究的目的是在实验动物模型中比较标准(SLA)和改良的喷砂和酸蚀(modSLA)植入物的早期骨整合特性。材料和方法:将共30枚SLA和modSLA植入物放置在三只绵羊的胫骨上,并进行插入扭矩值(ITV)和共振频率分析(RFA)测量。在3周和6周愈合的植入物上重复RFA测量,之后将动物处死以进行组织形态分析。在未脱钙的切片上评估骨与植入物的接触。六周愈合的植入物也接受了反向扭矩测试(RTT)。结果通过Friedman检验,Kruskal-Wallis检验和Spearman等级相关检验进行分析。结果:所有植入物均达到了强大的基本稳定性,ITV平均为36.13 + 2.47和35.47 +-2.85 N / cm。在手术阶段,发现SLA和modSLA植入物的RFA值分别为72.27±3.17和71.6±2.87。愈合3周后,modSLA植入物的平均BIC%(80.64 +-13.89%)和RFA值(76.8 +1.14)明显高于SLA植入物(64.39 +-21.2 BIC%和74.2)(P = 0.0002) +-4.76 RFA)。但是,愈合6周后,SLA和modSLA植入物之间没有统计学上的显着差异。两种植入物在RTT测试中均显示出相似的结果(SLA和modSLA植入物分别为115.2±4.14和117±4.47 N / cm)。在RFA和BIC%之间未发现相关性。结论:在该初步研究的范围内,可以得出结论,与SLA植入物相比,modSLA植入物在更早的时间点可获得更高的骨骼接触和稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号