...
首页> 外文期刊>Clinical oral implants research >Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments.
【24h】

Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments.

机译:钛与定制的氧化锆种植体基台相比,使用钛合金的牙齿-牙齿和种植体-牙齿支撑的全陶瓷固定局部义齿的断裂力。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: Tooth-coloured customised implant abutments and full ceramic supraconstructions thereon can be made of zirconia by computer-aided manufacturing (CAM). The aim of this study was to examine the potential limits of zirconia three-unit fixed partial dentures made on customised zirconia implant abutments in implant-tooth supported cases. MATERIAL AND METHODS: Rigidly mounted implants (XiVE-S diameter 3.8 mm; length 11 mm; Friadent, Germany) were placed in PMMA-moulds pairwise with human molars at a distance of 10 mm in groups #1 and #2. Control group #3 consisted of two molars without implant involvement. Beforehand all molar roots were covered with polyether (Impregum: 3 M Espe, Germany) to simulate periodontal mobility. The abutments in #1 were individually fabricated from CerconBase and luted on experimental titanium bases (both: DeguDent, Germany). In #2, industrially prefabricated titanium abutments (Friadent) were used. All molar teeth were provided with a circumferential chamfer preparation. Three-unit fixed partial dentures were fabricated from CerconBase/CerconKiss in a CAM-process (Material/devices: DeguDent) for all test groups (n=8/group). All fixed partial dentures were cemented with RelyXUnicem (3 M Espe), thermomechanically loaded (TCML=1.2 x 10(6) x 50 N; 6000 x 5 degrees /55 degrees) and fracture tested in a Universal Test Machine (UTM 1446: Zwick, Germany). RESULTS: None of the dentures failed during TCML, and the Cercon abutments showed no damage either to the bonding surface to titanium or to the ceramic itself. Two fixation screws in group #1 broke towards the end of TCML. Fracture test result (Median and 25-/75-Percentiles) were: #1 1190 (1046/2008), #2 991 (832/1402), #3 1331 (1224/1428). CONCLUSIONS: All restoration alternatives showed sufficient fracture resistance for posterior regions.
机译:目的:可以通过计算机辅助制造(CAM)由氧化锆制成牙齿色的定制种植体基台及其上的全陶瓷上覆结构。这项研究的目的是检查在种植牙支持的情况下,在定制的氧化锆种植体基台上制作的氧化锆三单元固定局部义齿的潜在限制。材料与方法:在第1组和第2组中,将刚性安装的植入物(XiVE-S直径3.8 mm;长度11 mm;德国Friadent)与人类臼齿成对放置在PMMA模具中,与人类臼齿成对,相距10 mm。对照组#3由两个磨牙组成,没有植入物参与。事先用聚醚(Impregum:3 M Espe,德国)覆盖所有臼齿根,以模拟牙周活动度。 #1中的基台由CerconBase单独制造,并以实验性的钛基材料(都来自德国DeguDent)为基础。在#2中,使用了工业预制的钛基台(Friadent)。所有臼齿均设有圆周倒角准备。对于所有测试组(n = 8 /组),由CerconBase / CerconKiss以CAM程序(材料/设备:DeguDent)制造三单元固定式局部义齿。所有固定的局部义齿均用RelyXUnicem(3 M Espe)固结,热机械加载(TCML = 1.2 x 10(6)x 50 N; 6000 x 5度/ 55度),并在通用试验机(UTM 1446:Zwick)中进行断裂测试,德国)。结果:在TCML期间,没有一个假牙失败,并且Cercon基台对钛的粘结表面或陶瓷本身均没有损坏。第1组中的两个固定螺钉在TCML快要结束时断裂。断裂测试结果(中位数和25- / 75%)为:#1 1190(1046/2008),#2 991(832/1402),#3 1331(1224/1428)。结论:所有修复方案均对后牙区显示出足够的抗裂性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号