PURPOSE: To evaluate motion artifacts, tissue contrasts, and lesion detectability in the neck with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) technique. MATERIALS AND METHODS: A total of 46 patients referred for MRI of the neck were included in a comparison of T2-weighted BLADE (T2W-BLADE) sequence and T2W fast spin-echo (T2W-FSE) sequence. All examinations were performed at 3T using the same parameters. Two observers evaluated unlabelled images for motion artifacts, the preferred image quality, and lesion detectability. Region of interest (ROI)-based quantitative measurements were performed to assess tissue contrasts. The frequency of occurrence of the different assessed artifacts and the lesion detectability was tested using McNemar's test. Tissue contrasts were compared using the Wilcoxon paired test. Reader agreement was assessed using kappa test. RESULTS: T2W-BLADE showed less ghosting and pulsation artifacts than T2W-FSE (P < 0.01). T2W-BLADE images were rated as better than or equal to T2W-FSE images in majority cases (93.5%; kappa = 0.64). There was not significant difference in tissue contrasts between T2W-BLADE and T2W-FSE. A total of 32 lesions were present in 32 patients and equally well seen on T2W-BLADE and T2W-FSE. CONCLUSION: T2W-BLADE can reduce motion artifacts and provide tissue contrasts and lesion detectability equivalent to T2W-FSE.
机译:目的:使用增强重建(PROPELLER)(BLADE)技术,通过周期性旋转的重叠平行线评估颈部的运动伪影,组织对比和病变检测能力。材料与方法:总共比较了46例接受颈部MRI检查的患者,比较了T2加权BLADE(T2W-BLADE)序列和T2W快速自旋回波(T2W-FSE)序列。所有检查均在3T下使用相同参数进行。两名观察者评估了未标记图像的运动伪影,首选图像质量和病变可检测性。进行基于感兴趣区域(ROI)的定量测​​量以评估组织对比。使用McNemar检验测试了不同评估伪影的出现频率和病变可检测性。使用Wilcoxon配对测试比较组织对比。使用kappa测验评估读者的认同感。结果:与T2W-FSE相比,T2W-BLADE显示出更少的重影和脉动伪影(P <0.01)。在大多数情况下,T2W-BLADE图像被评为优于或等于T2W-FSE图像(93.5%; k = 0.64)。 T2W-BLADE和T2W-FSE之间的组织对比度没有显着差异。在32例患者中共出现32个病变,在T2W-BLADE和T2W-FSE上同样清晰可见。结论:T2W-BLADE可以减少运动伪像,并提供与T2W-FSE等效的组织对比和病变检测能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号