Three-dimensional fast spoiled gradient-echo dual echo (3D-FSPGR-DE) with water reconstruction: preliminary experience with a novel pulse sequence for gadolinium-enhanced abdominal MR imaging.

机译:带水重建功能的三维快速变质梯度回波双回波(3D-FSPGR-DE):pulse增强腹部MR成像的新型脉冲序列的初步经验。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare three-dimensional fast spoiled gradient-echo dual-echo (3D-FSPGR-DE) with water reconstruction to conventional 3D-FSPGR for gadolinium-enhanced abdominal imaging. MATERIALS AND METHODS: Sixty-five patients underwent abdominal MRI on a 1.5T GE-HDx MR scanner using gadolinium-enhanced 3D-FSPGR and 3D-FSPGR-DE imaging. Qualitatively, FSPGR-DE and 3D-FSPGR images were reviewed side by side for normal anatomic structures, artifacts, and image quality. The images were reviewed separately for abnormalities of abdominal organs. Receiver operating characteristic (ROC) curve analysis was performed. Quantitative analysis measured mean signal intensity of liver, spleen, aorta, liver lesions, and noise. RESULTS: Observers preferred FSPGR-DE for evaluating liver, vessels, muscles, and subcutaneous tissues. Fat suppression was superior on FSPGR-DE in 63 (0.97) and 61 (0.94) of 65 cases for two observers. FSPGR-DE showed less susceptibility artifact in 47 (0.72) and 41 (0.63) cases, better signal in edge slices in 60 (0.92) and 60 (0.92) cases, less phase artifact in 42 (0.65) and 45 (0.69) cases, and less parallel imaging artifact in 13 (0.20) and 10 (0.15) cases. Images were equivalent for depicting abdominal findings with no difference in the area under the ROC curve. FSPGR-DE images showed a 20%, 29%, and 34% increase in liver, splenic, and aortic signal, respectively, and a 45% and 62% increase in liver-lesion contrast and contrast-to-noise ratio (CNR), respectively. CONCLUSION: Gadolinium-enhanced 3D-FSPGR-DE with water reconstruction provides volumetric abdominal imaging with superior image quality, more homogeneous fat suppression, reduced artifacts, and improved image signal and homogeneity.
机译:目的:比较具有水重建功能的三维快速变质梯度回波双回波(3D-FSPGR-DE)与用于3增强腹部成像的传统3D-FSPGR。材料与方法:65例患者在1.5T GE-HDx MR扫描仪上使用增强的3D-FSPGR和3D-FSPGR-DE成像进行了腹部MRI。定性地,对FSPGR-DE和3D-FSPGR图像进行了并排检查,以了解正常的解剖结构,伪影和图像质量。分别检查图像是否有腹部器官异常。进行接收器工作特性(ROC)曲线分析。定量分析测量了肝脏,脾脏,主动脉,肝脏病变和噪音的平均信号强度。结果:观察者更喜欢用FSPGR-DE评估肝脏,血管,肌肉和皮下组织。 FSPGR-DE的脂肪抑制作用在65例病例中有63例(0.97)和61例(0.94)优于两名观察者。 FSPGR-DE在47(0.72)和41(0.63)例中显示较少的磁化伪影,在60(0.92)和60(0.92)例中边缘切片中的信号更好,在42(0.65)和45(0.69)例中的相位伪影较少,在13(0.20)和10(0.15)情况下的平行成像伪影较少。图像等同于描绘腹部发现,但ROC曲线下的面积无差异。 FSPGR-DE图像显示肝脏,脾脏和主动脉信号分别增加20%,29%和34%,肝脏病变对比度和对比噪声比(CNR)分别增加45%和62% , 分别。结论with增强的3D-FSPGR-DE水重建技术可提供腹部容积成像,具有卓越的图像质量,更均匀的脂肪抑制作用,减少的伪影并改善了图像信号和均质性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号