PURPOSE: To investigate changes in image and dynamic signal-to-noise ratios (SNRs) of the DeltaR2* curve, as well as magnetic susceptibility-induced artifacts between a standard quadrature head coil and an eight-channel phased-array coil with and without sensitivity-encoding (SENSE) at 3T, compared to the current clinical standard head coil acquisition at 1.5T. MATERIALS AND METHODS: Dynamic susceptibility contrast (DSC) perfusion MRI was performed on 80 brain tumor patients using a gradient-echo, echo-planar imaging (EPI) sequence. Image and dynamic SNR were compared between 1.5T and 3T field strengths, a quadrature and eight-channel phased-array coil, and a conventional vs. partially parallel EPI acquisition with SENSE reconstruction. The amount of geometric distortion and signal dropout was quantified and compared between conventional and SENSE EPI acquisitions within the same exam at 3T. RESULTS: An initial 2.6-fold elevation in dynamic SNR was observed in normal-appearing white matter when doubling the field strength (P < 0.001), with an additional 1.7-fold increase found when employing an eight-channel phased-array coil (P < 0.002). Compared to the standard 3T eight-channel coil acquisition, the implementation of SENSE reduced the number of voxels experiencing large anterior shifts in the phase-encode direction, lowered the volume of signal dropout by 2.0-11.5%, and allowed a 1.4-fold increase in slice coverage, while only decreasing the dynamic SNR by 22%. CONCLUSION: SENSE EPI at 3T yielded a significant improvement in dynamic SNR over the 1.5T acquisitions. A significant reduction in magnetic susceptibility-induced artifacts was achieved with SENSE EPI compared to the standard EPI eight-channel coil acquisition at 3T.
机译:目的:研究DeltaR2 *曲线的图像和动态信噪比(SNR)的变化,以及标准正交磁头线圈和带有或不带有八通道相控阵线圈的磁化率引起的伪影3T时的灵敏度编码(SENSE),而当前在1.5T时获得的临床标准头线圈。材料与方法:采用梯度回波,回波平面成像(EPI)序列对80例脑肿瘤患者进行了动态磁化率造影(DSC)灌注MRI。在1.5T和3T场强,正交和八通道相控阵线圈以及采用SENSE重建的传统与部分并行EPI采集之间比较了图像和动态SNR。在3T的同一次考试中,对常规和SENSE EPI采集之间的几何失真和信号丢失量进行了量化和比较。结果:当场强加倍(P <0.001)时,在正常出现的白质中观察到动态SNR的最初2.6倍升高,而使用八通道相控阵线圈(P时,则发现额外增加1.7倍) <0.002)。与标准的3T 8通道线圈采集相比,SENSE的实现减少了在相位编码方向发生较大前移的体素数量,将信号丢失量降低了2.0-11.5%,并增加了1.4倍在切片覆盖率方面,同时仅将动态SNR降低了22%。结论:3T时的SENSE EPI比1.5T采集的动态SNR有了显着提高。与3T时的标准EPI八通道线圈采集相比,SENSE EPI显着减少了磁化率诱发的伪影。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号