...
首页> 外文期刊>Journal of Avian Medicine and Surgery >Measuring the Level of Agreement Between a Veterinary and a Human Point-of-Care Glucometer and a Laboratory Blood Analyzer in Hispaniolan Amazon Parrots (Amazona ventralis)
【24h】

Measuring the Level of Agreement Between a Veterinary and a Human Point-of-Care Glucometer and a Laboratory Blood Analyzer in Hispaniolan Amazon Parrots (Amazona ventralis)

机译:在西班牙裔亚马逊鹦鹉(Amazona ventralis)中测量兽医和人类护理点血糖仪以及实验室血液分析仪之间的协议水平

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Although abnormalities in blood glucose concentrations in avian species are not as common as they are in mammals, the inability to provide point-of-care glucose measurement likely results in underreporting and missed treatment opportunities. A veterinary glucometer that uses different optimization codes for specific groups of animals has been produced. To obtain data for a psittacine bird specific optimization code, as well as to calculate agreement between the veterinary glucometer, a standard human glucometer, and a laboratory analyzer, blood samples were obtained from 25 Hispaniolan Amazon parrots (Amazona ventralis) in a 2-phase study. In the initial phase, blood samples were obtained from 20 parrots twice at a 2-week interval. For each sample, the packed cell volume was determined, and the blood glucose concentration was measured by the veterinary glucometer. The rest of each sample was placed into a lithium heparin microtainer tube and centrifuged, and plasma was removed and frozen at 30 degrees C. Within 5 days, tubes were thawed, and blood glucose concentrations were measured with a laboratory analyzer. The data from both procedures were used to develop a psittacine bird specific code. For the second phase of the study, the same procedure was repeated twice at a 2-week interval in 25 birds to determine agreement between the veterinary glucometer, a standard human glucometer, and a laboratory analyzer. Neither glucometer was in good agreement with the laboratory analyzer (veterinary glucometer bias, 9.0; level of agreement, -38.1 to 56.2; standard glucometer bias, 69.4; level of agreement -17.8 to 156.7). Based on these results, the use of handheld glucometers in the diagnostic testing of Hispaniolan Amazon parrots and other psittacine birds cannot be recommended.
机译:尽管禽类中的血糖浓度异常不像哺乳动物中常见,但无法提供即时的血糖测量可能会导致漏报和错过治疗机会。已经生产出一种针对特定动物组使用不同优化代码的兽用血糖仪。为了获得针对psittacine禽类的特定优化代码的数据,并计算兽用血糖仪,标准人体血糖仪和实验室分析仪之间的一致性,从两阶段的25只西班牙裔亚马逊鹦鹉(Amazona ventralis)中获取血液样本研究。在初始阶段,每隔2周两次从20只鹦鹉中采集两次血样。对于每个样品,确定填充细胞的体积,并通过兽用血糖仪测量血糖浓度。将每个样品的其余部分放入肝素锂微容器管中并离心,除去血浆并在30摄氏度下冷冻。在5天内,将管解冻,并用实验室分析仪测量血糖浓度。两种方法的数据都用于开发鹦鹉螺鸟类特有的密码。对于研究的第二阶段,以25周为间隔,每2周间隔两次重复相同的步骤,以确定兽用血糖仪,标准人用血糖仪和实验室分析仪之间的一致性。血糖仪与实验室分析仪均无良好一致性(兽用血糖仪偏差为9.0;一致性水平为-38.1至56.2;标准血糖仪偏差为69.4;一致性水平为-17.8至156.7)。根据这些结果,不建议在西班牙裔亚马逊鹦鹉和其他鹦鹉鹦鹉鸟类的诊断测试中使用手持式血糖仪。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号