Bone Ingrowths to Press-Fit and Loose-Fit Implants: Comparisons between Titanium and Hydroxyapatite.

机译:压入式和散装式植入物的骨骼生长:钛和羟基磷灰石的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to investigate whether the coating of titanium (Ti) implants with hydroxyapatite (HA) might create a better fixation when titanium implants are implanted into a gap. In each of 16 rats, the medullary cavity of both femurs was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 1.5 mm. In a random manner the proximal part of the cavity in half of the bones was reamed once again to a diameter of 2.0 mm. Nails with a diameter of 1.5 mm and a length of 34 mm were then inserted into the medullary cavity of these bones with press fit at the distal half and a gap to the bone in the proximal half. In the remaining bones the whole medullary canal was reamed to a diameter of 2.0 mm, and nails with a diameter of 2.0 mm and a length of 34 mm were introduced. In all cases, either a pure Ti nail or a Ti nail entirely plasma sprayed with HA was used in a random manner. The surface roughness of the pure Ti was characterized by Ra 2.6 mum and Rt 22 mum. Ra of HA was 7.5 mum and Rt 52 mum. At sacrifice after 16 weeks, both femurs were dissected free from soft tissues and then immersed in fixative. A specimen slice of about 5 mm in thickness was prepared from the subtrochanteric region with a water-cooled band saw. Sample preparation for undecalcified tissue followed the internal guidelines at the laboratories of the Department of Biomaterials/Handicap Research. Generally, bone contact to the nails with HA coating was more predictable than was bone contact to the Ti nails. But due to rather large variations in bone contact between the samples, statistical analyses revealed non-significant differences between the 4 groups (p = 0.083). There were no significant differences between Ti and HA coated nails of 2.0 mm (p = 0.633), nor between Ti and HA coated nails of 1.5 mm (p = 0.924). The pooled values for the 2.0 mm nails showed significantly higher bone bonding contact than the pooled values of the 1.5 mm nails (p = 0.011). Our results, then, indicate that bone bonding contact to implants with a loose fit insertion is less predictable than in press fit insertion, and HA coating seemed to be more predictable than pure Ti. However, due to large variations between the samples, the differences did not reach significant levels.
机译:这项研究的目的是调查当将钛植入物植入缝隙中时,用羟基磷灰石(HA)覆盖的钛(Ti)植入物是否会产生更好的固定效果。在每只16只大鼠中,两个股骨的髓腔由转子从转子区进入。用钢毛刺将其依次扩孔至直径1.5毫米。以随机的方式再次将一半骨头中的空腔的近端部分扩孔至直径为2.0毫米。然后将直径为1.5毫米,长度为34毫米的钉子插入这些骨头的髓腔,并在远端半部压入配合,并在近端半部与骨头的间隙插入。在剩余的骨头中,将整个髓管扩孔至直径为2.0毫米,并引入直径为2.0毫米,长度为34毫米的指甲。在所有情况下,均以随机方式使用纯Ti指甲或完全等离子喷涂HA的Ti指甲。纯Ti的表面粗糙度的特征在于Ra为2.6μm,Rt为22μm。 HA的Ra为7.5μm,Rt为52μm。在16周后处死时,将两个股骨从软组织中解剖下来,然后浸入固定剂中。用水冷带锯从转子下区域制备厚度约5mm的样品切片。未脱钙组织的样品制备遵循生物材料/障碍研究部实验室的内部准则。通常,与HA涂层的骨头接触比与Ti指甲的骨头接触更容易预测。但是由于样品之间的骨骼接触差异很大,统计分析显示这4组之间无显着差异(p = 0.083)。 2.0 mm的Ti和HA涂层指甲之间无显着差异(p = 0.633),1.5 mm的Ti和HA涂层指甲之间无显着差异(p = 0.924)。与1.5毫米钉子的集合值相比,2.0毫米钉子的集合值显示出明显更高的骨粘合接触(p = 0.011)。因此,我们的结果表明,与压配合插入相比,骨配合接触与松配合插入的植入物更难预测,并且HA涂层似乎比纯钛更可预测。但是,由于样品之间的差异很大,差异并未达到显着水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号