The validity of the diametral disc test with a small flat ground has been established. The stress distribution was determined by a finite element method for a range of loading conditions. The results show that for the case of a point load, the failure is due to shear and compressive stresses at the loading point. Application of the diametral disc test for a ground flat was proposed and tested. The width of the flattened area must be less than 0.2 times the diameter of the disc to obtain accurate tensile strength. [References: 21]
机译:直径小的圆盘直径盘测试的有效性已经确定。应力分布是通过有限元方法确定的一系列载荷条件。结果表明,在点载荷的情况下,失效是由于载荷点处的剪切应力和压应力引起的。提出并测试了直径盘测试在地面上的应用。平坦区域的宽度必须小于圆盘直径的0.2倍,以获得准确的拉伸强度。 [参考:21]