Ambient desorption/ionization mass spectrometry (MS) has gained growing interest during the last decade due to its high analytical performance and yet simplicity. Here, one of the recently developed ambient desorption/ionization MS sources, the flowing atmospheric-pressure afterglow (FAPA) source, was investigated in detail regarding background ions and typical ionization patterns in the positive as well as the negative ion mode for a variety of compound classes, comprising alkanes, alcohols, aldehydes, ketones, carboxylic acids, organic peroxides and alkaloids. A broad range of signals for adducts and losses was found, besides the usually emphasized detection of quasimolecular ions, i.e.[M+H](+) and [M-H](-) in the positive and the negative mode, respectively. It was found that FAPA-MS is best suited for polar analytes containing nitrogen and/or oxygen functionalities, e.g.carboxylic acids, with low molecular weights and relatively high vapor pressures. In addition, the source was used in proof-of-principle studies, illustrating the capabilities and limitations of the technique: Firstly, traces of cocaine were detected and unambiguously identified on euro banknotes using FAPA ionization in combination with tandem MS, suggesting a correlation between cocaine abundance and age of the banknote. Secondly, FAPA-MS was used for the identification of acidic marker compounds in organic aerosol samples, indicating yet-undiscovered matrix and sample surface effects of ionization pathways in the afterglow region. Copyright (c) 2016 John Wiley & Sons, Ltd.
机译:在过去的十年中,环境解吸/电离质谱(MS)由于其高分析性能和简便性而引起了越来越多的关注。在此,针对各种离子源的正离子和负离子模式中的背景离子和典型电离模式,对最近开发的一种环境解吸/电离MS源(流动的大气压余辉(FAPA)源)进行了详细研究。化合物类别,包括烷烃,醇,醛,酮,羧酸,有机过氧化物和生物碱。除了通常强调的准分子离子检测,即在正和负模式下分别检测到[M + H](+)和[M-H](-)之外,还发现了广泛的加合物和损失信号。已经发现,FAPA-MS最适合于具有低分子量和相对高蒸气压的含有氮和/或氧官能团,例如羧酸的极性分析物。此外,该来源还用于原理验证研究中,说明了该技术的功能和局限性:首先,使用FAPA电离结合串联MS在欧元纸币上检测到可卡因的痕迹,并进行了明确鉴定,表明两者之间存在相关性。可卡因的丰度和钞票的年龄。其次,FAPA-MS用于鉴定有机气溶胶样品中的酸性标记化合物,表明余辉区域中尚未发现的基质和样品表面电离途径的表面效应。版权所有(c)2016 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号