首页> 外文期刊>Journal of mass spectrometry: JMS >Rapid screening and characterization of drug metabolites using a multiple ion monitoring-dependent MS/MS acquisition method on a hybrid triple quadrupole-linear ion trap mass spectrometer
【24h】

Rapid screening and characterization of drug metabolites using a multiple ion monitoring-dependent MS/MS acquisition method on a hybrid triple quadrupole-linear ion trap mass spectrometer

机译:在混合三重四极杆-线性离子阱质谱仪上使用依赖多离子监测的MS / MS采集方法快速筛选和表征药物代谢物

获取原文
获取原文并翻译 | 示例
           

摘要

A novel LC/MS/MS method that uses multiple ion monitoring (MIM) as a survey scan to trigger the acquisition of enhanced product ions (EPI) on a hybrid quadrupole-linear ion trap mass spectrometer (Q TRAP) was developed for drug metabolite identification. In the MIM experiment, multiple predicted metabolite ions were monitored in both Q1 and Q3. The collision energy in Q2 was set to a low value to minimize fragmentation. Results from analyzing ritonavir metabolites in rat hepatocytes demonstrate that MIM-EPI was capable of targeting a larger number of metabolites regardless of their fragmentation and retained sensitivity and duty cycle similar to multiple reaction monitoring (MRM)-EPI. MIM-based scanning methods were shown to be particularly useful in several applications. First, MIM-EPI enabled the sensitive detection and MS/MS acquisition of up to 100 predicted metabolites. Second, MIM-MRM-EPI was better than MRM-EPI in the analysis of metabolites that undergo either predictable or unpredictable fragmentation pathways. Finally, a combination of MIM-EPI and full-scan MS (EMS), as an alternative to EMS-EPI, was well suited for routine in vitro metabolite profiling. Overall, MIM-EPI significantly enhanced the metabolite identification capability of the hybrid triple quadrupole-linear ion trap LC/MS.
机译:针对药物代谢物开发了一种新颖的LC / MS / MS方法,该方法使用多离子监测(MIM)作为调查扫描来触发在混合四极杆-线性离子阱质谱仪(Q TRAP)上捕获增强的产物离子(EPI)识别。在MIM实验中,在Q1和Q3中都监测了多个预测的代谢物离子。将Q2中的碰撞能量设置为较低的值,以最大程度地减少碎片。分析大鼠肝细胞中利托那韦代谢物的结果表明,MIM-EPI能够靶向大量代谢物,而与多反应监测(MRM)-EPI一样,无论其碎片化程度如何,保留的敏感性和占空比也不同。事实证明,基于MIM的扫描方法在多种应用中特别有用。首先,MIM-EPI能够灵敏检测和MS / MS采集多达100种预测代谢物。其次,在经历可预测的或不可预测的片段化途径的代谢物分析中,MIM-MRM-EPI优于MRM-EPI。最后,MIM-EPI和全扫描MS(EMS)的组合作为EMS-EPI的替代品,非常适合常规的体外代谢产物分析。总体而言,MIM-EPI大大增强了混合三重四极杆-线性离子阱LC / MS的代谢物鉴定能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号