...
首页> 外文期刊>Journal of mass spectrometry: JMS >Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry
【24h】

Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

机译:液相色谱串联质谱法测定葡萄糖和甘油的浓度及其示踪剂富集

获取原文
获取原文并翻译 | 示例

摘要

The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments in connection to in vivo metabolic studies investigating glucose turnover and lipolytic rate. Moreover, in order to keep up with this new fast analysis, simple derivatization procedures have been developed. Prior to analysis, glucose and glycerol were derivatized using benzoyl chloride in order to form benzoylated derivatives via new simplified fast procedures. For glucose, two internal standards were evaluated, [U-C-13(6)]glucose and [U-C-13(6), D-7]glucose, and for glycerol, [U-C-13(3), D-8]glycerol was used. The method was validated by means of calibration curves, quality control samples, and plasma samples spiked with [6,6-D-2]glucose, [U-C-13(6)]glucose, and [1,1,2,3,3-D-5]glycerol in order to test accuracy, precision, and recovery of the method. Moreover, post preparative and freeze-thaw sample stability were tested. The correlation of calibration curves for the glucose concentration were r(2)=0.9998 for [U-C-13(6)]glucose and r(2)=0.9996 for [U-C-13(6), D-7]glucose, and r(2)=0.9995 for the glycerol concentration. Interday accuracy for glucose using [U-C-13(6)]glucose and glycerol determined in spiked plasma were respectively 103.5% and 106.0%, and the coefficients of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose and glycerol concentrations and enrichment of infused tracers most commonly used in human metabolic kinetic studies. Copyright (c) 2014 John Wiley & Sons, Ltd.
机译:本研究描述了一种新的液相色谱串联质谱法,该方法使用稳定的同位素标记的内标物对人血浆中的葡萄糖和甘油进行高通量定量分析,适用于同时测量葡萄糖和甘油富集度,并与研究葡萄糖的体内代谢研究相关周转率和脂解率。此外,为了跟上这种新的快速分析,已经开发了简单的衍生化程序。在分析之前,使用苯甲酰氯将葡萄糖和甘油衍生化,以便通过新的简化快速程序形成苯甲酰化衍生物。对于葡萄糖,评估了两个内标,[UC-13(6)]葡萄糖和[UC-13(6),D-7]葡萄糖,对于甘油,评估了[UC-13(3),D-8]甘油被使用了。该方法通过校准曲线,质量控制样品和掺有[6,6-D-2]葡萄糖,[UC-13(6)]葡萄糖和[1,1,2,3, 3-D-5]甘油以测试方法的准确性,精密度和回收率。此外,测试了制备后和冻融样品的稳定性。葡萄糖浓度的校正曲线的相关性,对于[UC-13(6)]葡萄糖为r(2)= 0.9998,对于[UC-13(6),D-7]葡萄糖和r(2)= 0.9996 (2)= 0.9995的甘油浓度。使用加标血浆中的[U-C-13(6)]葡萄糖和甘油的日间葡萄糖准确度分别为103.5%和106.0%,变异系数分别为2.0%和9.7%。衍生化后,血浆样品稳定至少14天。总之,我们已经开发并验证了一种新颖,准确,灵敏的高通量液相色谱串联质谱方法,用于同时测定葡萄糖和甘油的浓度以及富集人体代谢动力学研究中最常用的注入示踪剂。版权所有(c)2014 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号