首页> 外文期刊>Journal of mass spectrometry: JMS >Evaluation of the sensitivity of the 'Wiley registry of tandem mass spectral data, MSforID' with MS/MS data of the 'NIST/NIH/EPA mass spectral library'
【24h】

Evaluation of the sensitivity of the 'Wiley registry of tandem mass spectral data, MSforID' with MS/MS data of the 'NIST/NIH/EPA mass spectral library'

机译:使用“ NIST / NIH / EPA质谱库”的MS / MS数据评估“串联质谱数据的Wiley注册中心MSforID”的敏感性

获取原文
获取原文并翻译 | 示例
           

摘要

Tandem mass spectral libraries are versatile tools for small molecular identification finding application in forensic science, doping control, drug monitoring, food and environmental analysis, as well as metabolomics. Two important libraries are the 'Wiley Registry of Tandem Mass Spectral Data, MSforID' (Wiley Registry MSMS) and the collection of MS/MS spectra part of the 2011 edition of the 'NIST/NIH/EPA Mass Spectral Library' (NIST 11 MSMS). Herein, the sensitivity and robustness of the Wiley Registry MSMS were evaluated using spectra extracted from the NIST 11 MSMS library. The sample set was found to be heterogeneous in terms of mass spectral resolution, type of CID, as well as applied collision energies. Nevertheless, sensitive compound identification with a true positive identification rate ≥95% was possible using either the MSforID Search program or the NIST MS Search program 2.0g for matching. To rate the performance of the Wiley Registry MSMS, cross-validation experiments were repeated using subcollections of NIST 11 MSMS as reference library and spectra extracted from the Wiley Registry MSMS as positive controls. Unexpectedly, with both search algorithms tested, correct results were obtained in less than 88% of cases. We examined possible causes for the results of the cross validation study. The large number of precursor ions represented by a single tandem mass spectrum only was identified as the basic cause for the comparably lower sensitivity of the NIST library.
机译:串联质谱库是用于小分子鉴定的多功能工具,可用于法医学,掺杂控制,药物监测,食品和环境分析以及代谢组学中。两个重要的库是“串联质谱的Wiley注册中心MSforID”(Wiley注册MSMS)和2011年版“ NIST / NIH / EPA质谱库”中的MS / MS光谱部分(NIST 11 MSMS) )。本文中,使用从NIST 11 MSMS库中提取的光谱评估了Wiley Registry MSMS的灵敏度和鲁棒性。发现样品集在质谱分辨率,CID类型以及所施加的碰撞能量方面是异质的。尽管如此,使用MSforID搜索程序或NIST MS Search程序2.0g进行匹配,仍可以实现真实阳性识别率≥95%的敏感化合物鉴定。为了评估Wiley Registry MSMS的性能,使用NIST 11 MSMS的子集合作为参考库并从Wiley Registry MSMS提取的光谱作为阳性对照,重复进行交叉验证实验。出乎意料的是,通过测试这两种搜索算法,在不到88%的情况下获得了正确的结果。我们检查了交叉验证研究结果的可能原因。仅由一个串联质谱表示的大量前体离子被确定为NIST库灵敏度相对较低的根本原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号