INTRODUCTION: Catheter stability is a key prerequisite for a successful EP procedure. Remote magnetic navigation system (RMNS) was recently introduced for the manipulation of EP catheters. It may provide an improved catheter stability but this has not been tested prospectively. We performed a prospective cross-over study which compares the amplitude and stability of the His-electrogram obtained by catheters using RMNS vs conventional manual catheter placement. METHODS: His-electrograms were continuously recorded for 3 min with a conventional His mapping catheter and magnetically tipped catheter capable of alignment in the direction of an externally controlled magnetic field (0.08-0.1 Tesla) in the same patient. First 100 beats of each recording were used for data analysis. The amplitudes of each set of His-electrograms were measured and compared in microvolts. Coefficient of variation of the measured His-signal amplitude was calculated for each beat. Miller's test for the equality of the coefficients of variation and Levene's test of homogeneity of variance were used for statistical analysis. RESULTS: Fourteen patients (6 males; aged 48+/-25 years) were included in the study. His-electrograms were more stable and homogenous with RMNS than manual method in 10/14 patients. Pooled variance of all RMNS recordings was significantly less than pooled variance of manual recordings (p=0.01). CONCLUSION: His-electrogram recording using RMNS is more stable and homogeneous than traditional manual method in most patients. These data indicate a superior catheter stability with RMNS.
机译:引言:导管的稳定性是成功进行EP手术的关键前提。最近引入了远程磁导航系统(RMNS)来操纵EP导管。它可以提供改善的导管稳定性,但是尚未经过前瞻性测试。我们进行了一项前瞻性交叉研究,该研究比较了使用RMNS导管与常规手动导管放置所获得的His-电描记图的幅度和稳定性。方法:使用常规的His定位导管和能够在同一患者中沿外部控制磁场(0.08-0.1 Tesla)方向对齐的磁尖导管连续记录His-心电图3分钟。每个记录的前100个节拍用于数据分析。测量每组His电图的幅度,并以微伏为单位进行比较。计算每个拍的His信号幅度的变化系数。统计分析使用变异系数相等的Miller检验和方差均匀性的Levene检验进行统计分析。结果:该研究纳入了14名患者(6名男性;年龄48 +/- 25岁)。在10/14例患者中,与手动方法相比,RMNS的His心电图更加稳定且均一。所有RMNS记录的合并方差显着小于手动记录的合并方差(p = 0.01)。结论:在大多数患者中,使用RMNS进行His-electrogram记录比传统的手动方法更稳定,更均匀。这些数据表明RMNS具有优异的导管稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号