BACKGROUND & AIMS: The aim of this study was to see if a 170 degrees angle of view (wide angle [WA]) colonoscope allowed faster withdrawal without decreasing adenoma detection. METHODS: Eight colonoscopists at 2 institutions participated in the study. Patients were randomized so that each colonoscopist performed 50% of the exams with a 160 series (140 degrees angle of view; standard [ST]) colonoscope and 50% with a prototype 160 series colonoscope with a 170 degrees angle of view (WA instrument). Insertion and withdrawal times and number of polyps detected were recorded. Endoscopists were asked to withdraw as quickly as they could carefully complete the exams. Analysis of variance was done to compare insertion and withdrawal times and number of polyps detected. Time to perform biopsy, polypectomy, and cleaning was subtracted using a stopwatch. RESULTS: A total of 710 procedures were performed, 355 with ST and 355 with WA colonoscope. The mean insertion time was similar. The mean withdrawal time (absenttime for suctioning, washing, etc.) with the WA colonoscope was 4.9 min which was shorter (4.9 vs 5.4 min; P = .0001) overall and for three individual endoscopists (P = .0001, P = .01, and P = .03). There was no difference in the mean number of adenomas detected per colonoscopy with ST (0.6) compared to WA (0.5) (P = .12). Two of the three endoscopists with shorter withdrawal times with WA had numerically higher detection rates with WA. CONCLUSIONS: The WA colonoscope is associated with a reduction in withdrawal time without compromising adenoma detection. However, this effect is operator dependent and the overall impact of wide-angle optics in this study was minor.
机译:背景与目的:这项研究的目的是观察170度角(广角[WA])结肠镜是否可以在不降低腺瘤检测的情况下更快地撤药。方法:来自两个机构的八位结肠镜医师参加了这项研究。将患者随机分组,以便每位结肠镜检查人员使用160系列(140度视角;标准[ST])结肠镜进行50%的检查,并使用170度视角的原型160系列结肠镜(WA仪器)进行50%的检查。 。记录插入和退出的时间以及检测到的息肉数量。内镜医师被要求尽快退出考试,因为他们会认真完成考试。进行方差分析以比较插入和退出时间以及检测到的息肉数量。使用秒表减去进行活检,息肉切除和清洁的时间。结果:总共进行了710例手术,其中355例行ST手术,355例行WA结肠镜检查。平均插入时间相似。 WA结肠镜的平均撤药时间(无吸,洗等时间)为4.9分钟,这比整体上和三个内窥镜检查员的平均撤药时间(4.9 vs 5.4分钟; P = .0001)短(P = .0001,P =。 01,而P = .03)。与WA(0.5)相比,ST(0.6)结肠镜检查平均腺瘤数目无统计学差异(P = .12)。在WA撤药时间较短的三个内镜医师中,WA的检出率在数值上更高。结论:WA结肠镜可减少停药时间而不会损害腺瘤的检测。但是,这种影响取决于操作员,因此在本研究中,广角光学元件的总体影响很小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号