Rapid measurement of human milk macronutrients in the neonatal intensive care unit: Accuracy and precision of fourier transform mid-infrared spectroscopy

机译:新生儿重症监护室中人乳中大量营养元素的快速测定:傅立叶变换中红外光谱法的准确性和精密度

获取原文
获取原文并翻译 | 示例
       

摘要

Background: Although it is well established that human milk varies widely in macronutrient content, it remains common for human milk fortification for premature infants to be based on historic mean values. As a result, those caring for premature infants often underestimate protein intake. Rapid precise measurement of human milk protein, fat, and lactose to allow individualized fortification has been proposed for decades but remains elusive due to technical challenges. Objective: This study aimed to evaluate the accuracy and precision of a Fourier transform (FT) mid-infrared (IR) spectroscope in the neonatal intensive care unit to measure human milk fat, total protein, lactose, and calculated energy compared with standard chemical analyses. Methods: One hundred sixteen breast milk samples across lactation stages from women who delivered at term (n = 69) and preterm (n = 5) were analyzed with the FT mid-IR spectroscope and with standard chemical methods. Ten of the samples were tested in replicate using the FT mid-IR spectroscope to determine repeatability. Results: The agreement between the FT mid-IR spectroscope analysis and reference methods was high for protein and fat and moderate for lactose and energy. The intra-assay coefficients of variation for all outcomes were less than 3%. Conclusion: The FT mid-IR spectroscope demonstrated high accuracy in measurement of total protein and fat of preterm and term milk with high precision.
机译:背景:尽管众所周知,母乳中的常量营养素含量差异很大,但对于早产儿而言,其母乳强化仍然基于历史平均值。结果,那些照顾早产婴儿的人常常低估了蛋白质的摄入量。几十年来,已经提出了快速精确地测量人乳蛋白,脂肪和乳糖以实现个性化强化的方法,但是由于技术挑战,这种方法仍然难以捉摸。目的:本研究旨在评估新生儿重症监护病房中傅立叶变换(FT)中红外(IR)光谱仪与标准化学分析相比测量人乳脂肪,总蛋白,乳糖和计算出的能量的准确性和准确性。方法:使用FT中红外光谱仪和标准化学方法分析了足月(n = 69)和早产(n = 5)分娩的妇女在哺乳阶段的116份母乳样品。使用FT中红外光谱仪重复测试了十个样品,以确定可重复性。结果:FT中红外光谱仪分析和参考方法之间的蛋白质和脂肪一致性很高,而乳糖和能量的一致性中等。所有结果的测定内变异系数均小于3%。结论:FT中红外光谱仪显示了高精度的早产和足月牛奶中总蛋白质和脂肪的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号