首页> 外文期刊>Journal of human kinetics >Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility
【24h】

Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility

机译:膝关节伸肌的爆炸强度:标准试验检测方法对测量重现性的影响

获取原文
获取原文并翻译 | 示例
       

摘要

The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48-72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTDpeak) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0-30 to 0-300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTDpeak (version II). High ICC-values (0.80-0.99) and acceptable CV-values (1.9-8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of >= 100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTDpeak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse(0-30ms) and RTD/impulse(0-50ms)) showed clearly weaker reproducibility results (ICC: 0.53-0.84; CV: 7.3-16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTDpeak-trial.
机译:本研究旨在评估使用IsoMed 2000测力计在单关节等距膝盖伸展过程中爆炸强度测量值的重测重现性。在两次间隔48-72小时的时间中对31名身体活跃的男性受试者(平均年龄:23​​.7岁)进行了测量。对于(i)最大扭矩(MVC),(ii)扭矩发展的峰值速率(RTDpeak)和(iii)扭矩,计算类内相关系数(ICC 2,1)和变异系数(CV)。平均转矩发展速率(RTD)和在几个预定义的时间间隔(0-30至0-300 ms)内获得的脉冲;因此,爆炸强度变量在两个概念上不同的版本中得出:一方面是从MVC试用版(版本I)获得,另一方面是从显示RTDpeak的试验中获得(版本II)。无论是版本I还是版本I,对于MVC以及RTD都可以找到较高的ICC值(0.80-0.99)和可接受的CV值(1.9-8.7%),以及以> = 100 ms的时间间隔获取的脉冲II被使用。相比之下,RTDpeak以及RTD的测量以及在非常早的收缩阶段(即RTD /冲动(0-30ms)和RTD /冲动(0-50ms))采集的脉冲显示出明显较差的重现性结果(ICC: 0.53-0.84; CV:7.3-16.4%),并引起了对临床实用性的怀疑,尤其是当使用版本I推导时。但是,如果需要在实践中在较早的时间间隔内测量爆炸强度,考虑到更强的可重复性结果,建议重点研究基于RTDpeak试用版第二版的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号