首页> 外文期刊>Journal of Hand Surgery. American Volume >Radiographic alignment of unstable distal radius fractures fixed with 1 or 2 rows of screws in volar locking plates
【24h】

Radiographic alignment of unstable distal radius fractures fixed with 1 or 2 rows of screws in volar locking plates

机译:不稳定的distal骨远端骨折的影像学对准,在掌侧锁定板上用1或2排螺钉固定

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: We tested the null hypothesis that there is no difference in the change in volar tilt of the articular surface of the distal radius on lateral radiographs obtained before suture removal and 3 months or more after surgical fracture fixation when 1 or 2 rows of screws are used in the distal part of a volar locked plate. Methods: We retrospectively identified 364 consecutive patients with a distal radius fracture treated by 2 surgeons with open reduction and volar locked plate fixation between 2007 and 2011 at our institution. A manually case-matched design with one-to-one matching of 2 different strategies for screws in the distal part of the plate (1 row versus 2 rows) on the basis of sex, AO type, presence of dorsal comminution, ulna fracture, mechanism of injury, and age (?? 8 y) resulted in a group of 34 pairs, 68 total fractures. Radiographic alignment was measured before suture removal and 3 months or more after surgery. Results: The change in volar tilt of the articular surface was -1.2?? in the 1-row group and -0.9?? in the 2-row group, which was not significantly different. The secondary displacement of radial inclination and ulnar variance were likewise small and not statistically significant. Conclusions: We found no advantage of 2 rows of distal screws over a single row of screws with respect to maintenance of achieved restoration of volar angulation after volar locked plate fixation of AO type A and C fractures of the distal radius. Type of study/level of evidence: Therapeutic III. ? 2013 American Society for Surgery of the Hand.
机译:目的:我们检验了零假设,即在拆线前和手术骨折固定后3个月或更长时间(使用1或2排螺钉)后获得的侧位X线照片上,radius骨远端关节面的掌侧倾斜变化无差异。用于手掌锁定板的远端。方法:我们回顾性分析了2007年至2011年间由364例行切开复位手掌锁定钢板固定术的treated骨远端骨折患者364例。手动案例匹配设计,根据性别,AO类型,背粉碎性骨折,尺骨骨折,损伤的机理和年龄(?8 y)导致一组34对,共68处骨折。在拆线前和手术后3个月或更长时间测量射线照相对准。结果:关节面掌侧倾角变化为-1.2?在1行组中,-0.9?在2行组中,这没有显着差异。 radial骨倾角和尺骨变异的继发移位同样很小,在统计学上不显着。结论:我们发现在行radius骨锁定钢板固定远端of骨A型和C型骨折的掌骨锁定钢板后,维持两行远侧螺钉相对于单排螺钉没有优势。研究类型/证据级别:治疗III。 ? 2013年美国手外科学会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号