...
首页> 外文期刊>Journal of Immunological Methods >Flow cytometric determination of intracellular or secreted IFNgamma for the quantification of antigen reactive T cells.
【24h】

Flow cytometric determination of intracellular or secreted IFNgamma for the quantification of antigen reactive T cells.

机译:细胞内或分泌的IFNγ的流式细胞仪测定,用于定量抗原反应性T细胞。

获取原文
获取原文并翻译 | 示例
           

摘要

The detection of antigen-induced IFNgamma secretion at the single cell level can be used to identify and enumerate antigen-reactive T cells from peripheral blood. This study was performed to analyze the suitability of T cell enumeration by flow cytometry in comparison with the ELISPOT assay. Peripheral blood mononuclear cell (PBMC) samples from six HLA-A2+ healthy subjects were analysed for the frequency of influenza-reactive CD8+ T cells by flow cytometry detecting either intracellular IFNgamma (IC-FC) or secreted IFNgamma (S-FC). All samples were also analysed by IFNgamma ELISPOT assay. The frequency of influenza peptide-reactive T cells determined by IC-FC was 0.01 to 0.34% of CD8+ T cells and by ELISPOT assay 0.02 to 0.23% of CD8+ T cells (n=6 subjects) with a high inter-assay reproducibility and a close correlation between the assays (r=0.77, P<0.001). Little or no IFNgamma production was observed in unstimulated PBMC samples using either the IC-FC or the ELISPOT assay. In contrast, using S-FC large numbers of IFNgamma-secreting CD8+ T cells (0.37% to 5.55%, n=6 subjects) were detected in unstimulated PBMC. The frequency of influenza-reactive CD8+ T cells (0.57-5.19%, n=6 subjects) determined by S-FC did not correlate with the values from the IC-FC or ELISPOT assays. This comparative study shows the suitability of the determination of frequencies of antigen reactive T cells in PBMC by IC-FC. The advantage of IC-FC is the possibility to phenotype simultaneously antigen-reactive T cells.
机译:在单细胞水平上检测抗原诱导的IFNγ分泌可用于鉴定和计数外周血中的抗原反应性T细胞。进行这项研究以分析流式细胞仪与ELISPOT分析相比T细胞计数的适用性。通过流式细胞术检测细胞内IFNgamma(IC-FC)或分泌的IFNgamma(S-FC),分析了六名HLA-A2 +健康受试者的外周血单核细胞(PBMC)样本中流感反应性CD8 + T细胞的频率。还通过IFNγELISPOT测定法分析了所有样品。通过IC-FC确定的流感肽反应性T细胞的频率为CD8 + T细胞的0.01%至0.34%,通过ELISPOT分析确定为CD8 + T细胞的0.02%至0.23%的CD8 + T细胞(组间重复性高)测定之间的密切相关性(r = 0.77,P <0.001)。使用IC-FC或ELISPOT分析,在未刺激的PBMC样品中观察到很少或没有IFNγ产生。相反,使用S-FC在未刺激的PBMC中检测到大量分泌IFNγ的CD8 + T细胞(0.37%至5.55%,n = 6个受试者)。通过S-FC测定的流感反应性CD8 + T细胞(0.57-5.19%,n = 6个受试者)的频率与IC-FC或ELISPOT分析的值不相关。这项比较研究表明,用IC-FC测定PBMC中抗原反应性T细胞的频率是合适的。 IC-FC的优势在于可以同时对抗原反应性T细胞进行表型化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号