A microcomputer software package for determining the concentration of either the antibody or antigen from ELISA data for IBM PC compatible is presented. In the program optical densities (OD) and fluorescence obtained from 96-well ELISA plate can be input either directly, by interfacing with different brands of microplate reader such as Multiskan II Plus and Organon Teknika to the computer or manually. This software utilizes some mathematical and statistical models to fit the standard curve of each assay and interpolate analyte concentration using data from OD or fluorescence measurements. Cubic spline (Guardabasso et al., 1988), bezier and polynomial (Rodbard, 1979; Baud et al., 1991) interpolation formulas can be used to fit the data over the entire range for estimating the antibody or antigen concentration of the unknown samples whose OD or fluorescence is beyond the entire range. This software package, based on the concentration values of the analyte determined in different fluids (Nunez et al., 1994; Morales et al., 1994) and with some rules and algorithms, is used to calculate the parameters of screening and diagnostic tests such as sensitivity, specificity and predictive values (Coughlin et al., 1992). With the construction of the Receiver Operating Characteristic (ROC) curve it is possible to analyse different values of the sensitivity and specificity of the screening and diagnostic tests. A comparative statistical test for two populations that are non-normally distributed using a non-parametric Mann-Whitney test is provided. This software is an expandable tool designed for general use in clinical and experimental applications, including diagnostic and screening tests.
机译:提出了一种微型计算机软件包,用于从ELISA数据确定与IBM PC兼容的抗体或抗原的浓度。在程序中,可以通过与不同品牌的微孔板读取器(例如Multiskan II Plus和Organon Teknika)连接到计算机,或直接将从96孔ELISA板获得的光密度(OD)和荧光输入。该软件利用一些数学和统计模型来拟合每个测定的标准曲线,并使用OD或荧光测量数据插值分析物浓度。三次样条曲线(Guardabasso等人,1988),贝塞尔曲线和多项式(Rodbard,1979; Baud等人,1991)插值公式可用于拟合整个范围内的数据,以估计未知样品的抗体或抗原浓度OD或荧光超出整个范围。该软件包基于在不同流体中确定的分析物浓度值(Nunez等,1994; Morales等,1994)并使用一些规则和算法来计算筛选和诊断测试的参数,例如作为敏感性,特异性和预测值(Coughlin等,1992)。通过构建接收器工作特性(ROC)曲线,可以分析筛选和诊断测试的灵敏度和特异性的不同值。提供了使用非参数Mann-Whitney检验的两个非正态分布的总体的比较统计检验。该软件是可扩展的工具,设计用于临床和实验应用,包括诊断和筛查测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号