首页> 外文期刊>Journal of Immunological Methods >Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs. non-allergics.
【24h】

Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs. non-allergics.

机译:使用基于微粒的流式细胞仪同时测量一个人的眼泪样品中的六种细胞因子:过敏与非过敏。

获取原文
获取原文并翻译 | 示例
           

摘要

Tears play an essential role in maintaining corneal and conjunctival integrity by providing a tightly regulated, optimal extracellular environment critical to its numerous functions, which include anti-microbial defense, wound healing and inflammatory responses such as allergies. Elevated levels of inflammatory cytokines have been reported in tears from various ocular disease states. Characterization of tear cytokines has been limited by the small volume (microliter amounts) attainable. This limitation was addressed with the newly developed Becton Dickinson Cytometric Bead Array (CBA), which combines the principles of the "sandwich" immunoassay with the capability of flow cytometry for simultaneous measurement of the characteristics of multiple particles. This technique allows determination of six human cytokine (IFNgamma, TNFalpha, IL-2, IL-4, IL-5, IL-10) concentrations simultaneously in a single tear sample. Tears were collected from the inferior fornix of non-allergic (n=7) and allergic (n=9) donors. Each tear sample or cytokine standard was incubated with a mixture of capture Ab-bead reagent and detector Ab-phycoerythrin (PE) reagent, and analyzed using flow cytometry. All six cytokines were detectable in both non-allergic and allergic tears. Tears from allergic donors contained significantly less IL-10 (p=0.035), and had significant increases in the ratios of TNFalpha/IFNgamma, IL-5/IFNgamma and IL-5/IL-10 (p=0.0008, 0.0124 and 0.011, respectively). The small volume required (5-10 microl/test) by the Cytometric Bead Array allows measurement of all six cytokines from a single collection of tears. This decreases collection time, minimizing the confounding effect of stimulation on cytokine concentration in tears, as well as allowing calculation of cytokine ratios.
机译:眼泪通过提供对其多种功能至关重要的严格调节的最佳细胞外环境,在维持角膜和结膜完整性中起着至关重要的作用,这些环境包括抗微生物防御,伤口愈合和炎症反应(例如过敏)。据报道,各种眼病状态的眼泪中炎性细胞因子水平升高。泪液细胞因子的表征受到可获得的小体积(微升量)的限制。新开发的Becton Dickinson细胞计数珠阵列(CBA)解决了这一局限,该阵列将“三明治”免疫测定的原理与流式细胞仪的功能相结合,可同时测量多个颗粒的特征。该技术可在单个眼泪样品中同时测定六种人细胞因子(IFNgamma,TNFalpha,IL-2,IL-4,IL-5,IL-10)的浓度。从非过敏性供体(n = 7)和过敏性供体(n = 9)供者的下穹collected收集眼泪。将每种眼泪样品或细胞因子标准品与捕获Ab-bead试剂和检测器Ab-藻红蛋白(PE)试剂的混合物一起孵育,并使用流式细胞仪进行分析。在非过敏性和过敏性眼泪中都可以检测到所有六种细胞因子。来自过敏性供体的眼泪中IL-10的含量显着降低(p = 0.035),TNFalpha / IFNgamma,IL-5 / IFNgamma和IL-5 / IL-10的比例显着增加(p = 0.0008、0.0124和0.011,分别)。 Cytometric Bead Array所需的体积很小(5-10微升/测试),可从一次眼泪采集中测量所有六种细胞因子。这减少了收集时间,最大程度地减少了刺激对眼泪中细胞因子浓度的混杂影响,并允许计算细胞因子比率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号