The role of planar scintimammography with high-resolution dedicated breast camera in the diagnosis of primary breast cancer.

机译:平面闪烁乳房X线照相术与高分辨率专用乳腺照相机在诊断原发性乳腺癌中的作用。

获取原文
获取原文并翻译 | 示例
           

摘要

Planar scintimammography (SM) acquired with a conventional gamma camera has proved a useful complementary tool to mammography (Mx) in breast cancer (BC) diagnosis, but with unsatisfactory sensitivity in small size carcinomas. In this study we assessed the role of planar SM with a high-resolution dedicated breast camera (DBC) in BC diagnosis, comparing the results with those of Mx.A consecutive series of 145 patients scheduled for biopsy for suspected BC underwent Tc-99m tetrofosmin planar SM using a newly developed DBC. Scintigraphic data were compared with Mx findings and correlated to histology.Histopathologic analysis revealed 165 lesions: 143 malignant and 22 benign. SM detected 139/143 carcinomas (overall sensitivity: 97.2%) and was true negative in 19/22 benign lesions (overall specificity: 86.4%). SM sensitivity was 91% in < or =10-mm carcinomas. SM was more accurate than Mx in 42/145 cases (29%), detecting cancer in 9 patients with Mx indeterminate for dense breasts (8/9 tumors were <10 mm), assessing additional tumor foci (all <10 mm) in 5 points with multifocal disease and correctly classifying 28 patients with inconclusive mammographic findings as affected by cancer or by benign disease. Mx was more accurate than SM in 3 patients, in each detecting 1 subcentimeter BC false negative on SM.DBC planar SM seems a highly sensitive diagnostic tool in the detection of BC, even when small in size, and in the assessment of multifocal disease. A wider employment of this procedure is thus suggested, especially in indeterminate or inconclusive mammographic findings to improve sensitivity and specificity of Mx.
机译:事实证明,使用常规伽马照相机进行的平面闪烁X线摄影(SM)是乳腺X线摄影(Mx)在乳腺癌(BC)诊断中的有用补充工具,但在小尺寸癌中敏感性不足。在这项研究中,我们使用高分辨率专用乳腺摄像头(DBC)评估了平面SM在BC诊断中的作用,并将结果与​​Mx进行了比较。连续145例计划进行疑似BC活检的患者接受了Tc-99m替罗福明治疗使用新开发的DBC的平面SM。将闪烁图像数据与Mx表现进行比较,并与组织学相关联。组织病理学分析显示有165个病变:143例恶性和22例良性。 SM检测到139/143癌(总体敏感性:97.2%),在19/22良性病变中为阴性(总体特异性:86.4%)。在≤10 mm的癌中,SM敏感性为91%。 SM在42/145例中比Mx准确(29%),在9例Mx不确定的致密性乳癌患者中检测出癌症(8/9肿瘤<10 mm),在5例中评估了其他肿瘤灶(均<10 mm)指出患有多灶性疾病的患者,并正确分类了28例因乳腺癌或良性疾病而尚无定论的X线摄影检查的患者。在3例患者中,Mx比SM更准确,每例患者在SM上检测到1厘米以下的BC假阴性.DBC平面SM似乎是检测BC的高度灵敏的诊断工具,即使尺寸很小,也可用于评估多灶性疾病。因此,建议更广泛地使用该程序,特别是在不确定或不确定的乳腺X线摄影结果中,以提高Mx的敏感性和特异性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号