Hardware failure: a potential pitfall in assessing recurrent Ewing's sarcoma on bone scintigraphy.

机译:硬件故障:在骨闪烁显像仪上评估尤因氏肉瘤复发的潜在陷阱。

获取原文
获取原文并翻译 | 示例
           

摘要

A 14-year-old boy was treated for nonmetastasized femoral Ewing sarcoma with inductive and consolidation chemotherapy with surgical resection of the diaphysis and with interposition of an allograft. During follow-up, a remarkable increase in osteoblastic activity in the distal osteotomy plane was observed on Tc-99m disodium hydroxymethylene diphosphonate (HDP) scin-tigraphy 29 months after surgery that was highly suspicious of recurrence. Revision of radiographs showed delayed consolidation, induced by failure of hardware as the cause of increased tracer uptake. This was confirmed 6 months later by scintigraphy. It is concluded that bone scintigrams should be interpreted with available conventional x-rays to avoid false-positive results.
机译:一名14岁男孩接受了诱导性和巩固性化疗,并通过骨干切除术和同种异体移植治疗了非转移性股尤文氏肉瘤。在随访期间,在术后29个月的Tc-99m羟甲基二膦酸二钠二钠(HDP)闪烁成像中观察到远侧截骨平面成骨细胞活性显着增加,这极有可能复发。射线照片的修订显示,由于硬件故障导致示踪剂摄取增加,导致固结延迟。闪烁显像法在6个月后证实了这一点。结论是,应该用可用的常规X射线解释骨闪烁图,以避免假阳性结果。