OBJECTIVES: Secondary analysis of clinical trial data suggests visit-to-visit variability (VVV) of blood pressure is strongly associated with the incidence of cardiovascular disease. Measurement of blood pressure in usual practice settings may be subject to substantial error, calling into question the value of VVV in real-world settings. METHODS: We analyzed data on adults of at least 65 years of age with diagnosed hypertension who were taking antihypertensive medication from the Cohort Study of Medication Adherence among Older Adults (n = 772 with 14 or more blood pressure measurements). All blood pressure measurements, taken as part of routine outpatient care over a median of 2.8 years, were abstracted from patients' medical charts. RESULTS: Using each participant's first seven SBP measurements, the mean intraindividual standard deviation was 13.5 mmHg. The intraclass correlation coefficient for the standard deviation based on the first seven and second seven SBP measurements was 0.28 [95% confidence interval (CI) 0.20-0.34]. Individuals in the highest quintile of standard deviation of SBP based on their first seven measurements were more likely to be in the highest quintile of VVV using their second seven measurements (observed/expected ratio = 1.71, 95% CI 1.29-2.22). Results were similar for other metrics of VVV. The intraclass correlation coefficient was lower for DBP than SBP. CONCLUSION: These data suggest VVV of SBP measured in a real-world setting is not random. Future studies are needed to assess the prognostic value of VVV of SBP assessed in routine clinical practice.
机译:目的:对临床试验数据的二次分析表明,血压的访视变异性(VVV)与心血管疾病的发生率密切相关。在常规操作环境中的血压测量可能会出现重大误差,这使实际环境中的VVV值受到质疑。方法:我们分析了至少65岁的确诊为高血压的成年人的数据,这些数据来自老年药物依从性队列研究(n = 772,有14次或更多血压测量),正在服用降压药。所有血压测量值均取自2.8年来的中位门诊常规护理,这些数据均摘自患者的病历表。结果:使用每个参与者的前七个SBP测量值,平均车内个人标准差为13.5 mmHg。基于前七个和第二个七个SBP测量值的标准偏差的类内相关系数是0.28 [95%置信区间(CI)0.20-0.34]。根据他们的前七个测量值,在SBP标准偏差的最高五分位数中的个人使用其后七个测量值,更有可能在VVV的最高五分位数中(观察/期望比率= 1.71,95%CI 1.29-2.22)。其他VVV指标的结果相似。 DBP的类内相关系数低于SBP。结论:这些数据表明,在实际环境中测得的SBP的VVV不是随机的。需要进一步的研究来评估在常规临床实践中评估的SBP的VVV的预后价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号