Objective To validate an algorithm for the interpretation of automated office blood pressure (AOBP) measurement based upon data from untreated patients referred by physicians in the community for 24-h ambulatory blood pressure monitoring (ABPM).Methods An algorithm for interpreting AOBP readings was developed taking into account the previously documented equivalence of AOBP and mean awake ambulatory BP (ABP; mmHg), which were each classified as optimum BP ?0/80), borderline BP (130-139/80-89) and hypertension (>140/90). This classification was applied to data derived from 254 untreated patients undergoing 24-h ABPM, AOBP and routine manual BP taken at the patient's own family physician's office.
机译:目的根据社区医生转诊的未治疗患者的数据对24小时动态血压监测(ABPM)进行验证,以解释用于解释自动办公室血压(AOBP)的算法。方法提出了一种用于解释AOBP读数的算法考虑到以前记录的AOBP和平均清醒门诊BP(ABP; mmHg)的等效性,它们分别被分类为最佳BPα0/ 80,临界BP(130-139 / 80-89)和高血压(> 140 / 90)。该分类适用于来自254名未经治疗的患者的数据,这些患者接受了24小时ABPM,AOBP和在患者自己的家庭医生办公室进行的常规手动BP。