OBJECTIVES: Brachial artery flow-mediated dilation (FMD) is associated with risk factors providing information on cardiovascular prognosis. Despite the large effort to standardize the methodology, the FMD examination is still characterized by problems of reproducibility and reliability that can be partially overcome with the use of automatic systems. We developed real-time software for the assessment of brachial FMD (FMD Studio, Institute of Clinical Physiology, Pisa, Italy) from ultrasound images. The aim of this study is to compare our system with another automatic method (Brachial Analyzer, MIA LLC, IA, USA) which is currently considered as a reference method in FMD assessment. METHODS: The agreement between systems was assessed as follows. Protocol 1: Mean baseline (Basal), maximal (Max) brachial artery diameter after forearm ischemia and FMD, calculated as maximal percentage diameter increase, have been evaluated in 60 recorded FMD sequences. Protocol 2: Values of diameter and FMD have been evaluated in 618 frames extracted from 12 sequences. RESULTS: All biases are negligible and standard deviations of the differences are satisfactory (protocol 1: -0.27 +/- 0.59%; protocol 2: -0.26 +/- 0.61%) for FMD measurements. Analysis times were reduced (-33%) when FMD Studio is used. Rejected examinations due to the poor quality were 2% with the FMD Studio and 5% with the Brachial Analyzer. CONCLUSIONS: In conclusion, the compared systems show a optimal grade of agreement and they can be used interchangeably. Thus, the use of a system characterized by real-time functionalities could represent a referral method for assessing endothelial function in clinical trials.
机译:目的:肱动脉血流介导的扩张(FMD)与危险因素有关,可提供有关心血管预后的信息。尽管为标准化方法付出了巨大的努力,但FMD检查仍然具有可再现性和可靠性问题,这些问题可以通过使用自动系统来部分解决。我们开发了用于评估超声图像的肱FMD的实时软件(FMD Studio,意大利比萨临床生理研究所)。这项研究的目的是将我们的系统与另一种自动方法(Brachial Analyzer,MIA LLC,IA,USA)进行比较,该方法目前被视为FMD评估中的参考方法。方法:系统之间的一致性评估如下。方案1:在60条记录的FMD序列中评估了平均基线(基础),前臂缺血和FMD后最大肱动脉直径(以最大直径增加百分比计算)。方案2:在从12个序列中提取的618个帧中评估了直径和FMD的值。结果:对于FMD测量,所有偏差均可以忽略,并且差异的标准偏差令人满意(协议1:-0.27 +/- 0.59%;协议2:-0.26 +/- 0.61%)。使用FMD Studio时,分析时间减少了(-33%)。由于质量差而被拒绝的检查在FMD Studio中为2%,在肱臂分析仪中为5%。结论:总之,比较的系统显示出最佳的协议等级,可以互换使用。因此,使用以实时功能为特征的系统可以代表临床试验中评估内皮功能的推荐方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号