BACKGROUND AND OBJECTIVE: The European Lacidipine Study of Atherosclerosis (ELSA) is a prospective, randomized, double-blind, multi-national interventional trial to determine the effect of four-year treatment using the calcium antagonist lacidipine versus the beta-blocker atenolol on the progression of carotid atherosclerosis in 2259 asymptomatic hypertensive patients. B-mode ultrasound is used to measure the primary and secondary endpoints including the mean maximum intima-media thickness (IMT) of the carotid bifurcations and the common carotid arteries (CBM(max)), the mean maximum IMT of 12 standard carotid sites (M(max)) and the overall maximum IMT (T(max)). This paper reports the cross-sectional reproducibility of ultrasound measurements at baseline. METHOD: To evaluate measurement reliability, each patient is scanned twice at baseline and again at four annual visits, with 80% of the replicate scans performed by the same sonographer and 20% by a different sonographer; 50% of the replicate scans are read by the same reader and the other 50% by different readers. RESULTS: The overall coefficient of reliability (R) was 0.859 for CBM(max), 0.872 for M(max) and 0.794 for T(max). The reliability for CBM(max) was stable during the 1 3/4-year baseline period (R = 0.848 to 0.953) and was uniform among the 23 field centres (R = 0.798 to 0.926). Intra- and inter-reader reliability were 0.915 and 0.872 respectively, and intra-sonographer reliability was 0.866. CONCLUSION: The results demonstrate that by implementing standardized protocols and strict quality control procedures, highly reliable ultrasonic measurements of carotid artery IMT can be achieved in large multi-national trials.
机译:背景与目的:欧洲拉西地平动脉粥样硬化研究(ELSA)是一项前瞻性,随机,双盲,多国干预性试验,旨在确定使用钙拮抗剂拉西地平与β受体阻滞剂阿替洛尔进行四年治疗的效果。 2259名无症状高血压患者的颈动脉粥样硬化进展。 B型超声用于测量主要和次要终点,包括颈动脉分叉和颈总动脉的平均最大内膜中层厚度(IMT),12个标准颈动脉部位的平均最大IMT( M(max))和整体最大IMT(T(max))。本文报告了基线时超声测量的横截面再现性。方法:为评估测量的可靠性,每位患者在基线时进行两次扫描,并在每年四次访问时再次进行扫描,其中80%的重复扫描由同一位超声检查者进行,而20%由另一位超声检查者进行; 50%的重复扫描由同一读取器读取,其他50%由不同的读取器读取。结果:CBM(max)的整体可靠性系数(R)为0.859,M(max)的整体可靠性系数(R)为T(max)的0.772。 CBM(max)的可靠性在1 3/4年的基准期内是稳定的(R = 0.848至0.953),在23个现场中心之间是一致的(R = 0.798至0.926)。阅读器内和阅读器间的可靠性分别为0.915和0.872,超声检查仪内的可靠性为0.866。结论:结果表明,通过实施标准化协议和严格的质量控制程序,可以在大型跨国试验中实现对颈动脉IMT的高度可靠的超声测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号