Infrared spectrometry based 13C-octanoic acid breath test in measuring human solid gastric emptying.

机译:基于13 C-辛酸呼气试验的红外光谱法,用于测量人的固体胃排空。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND AIMS: Because of the convenience of non-dispersive infrared spectrometry (NDIRS), we attempted to validate the usefulness of NDIRS compared with scintigraphy in human solid gastric emptying (GE) measurement, and tried to establish the normal range of solid GE based on NDIRS. METHODS: Twelve healthy volunteers (three men, nine women) were recruited for simultaneous scintigraphy and 13C-octanoic acid breath test (13C-OABT) studies. Stomach half-emptying time (t1/2) and lag phase (tlag) were the two main GE parameters measured and correlated. The breath samples were analyzed using NDIRS every 10-15 min for a total of 6 h, while scintigraphy was taken minute by minute for the first 30 min, then hourly for 4 h. Another 32 healthy volunteers (19 men, 13 women) received only the 13C-OABT to measure their solid GE. RESULTS: A significant correlation for t1/2 was found between the breath test and scintigraphy (r = 0.85, P = 0.001), while tlag was also positively correlated (r = 0.73, P = 0.007). The reference range of t1/2B based on all 44 subjects was 89.4-185.1 min (135.9 +/- 21.1 min (mean +/- SD)), while the range for tlagB was 37.1-117.8 min (81.9 +/- 17.4 min). No demographic characteristics were found to influence the GE parameters. CONCLUSIONS: 13C-octanoic acid breath test determined by NDIRS is a simple, non-invasive and reliable measurement, which may provide an 'office-based' tool to detect solid GE.
机译:背景与目的:由于非分散红外光谱法(NDIRS)的便利性,我们试图验证NDIRS与闪烁显像法相比在人体固体胃排空(GE)测量中的有效性,并试图建立基于固体GE的正常范围在NDIRS上。方法:招募了12名健康志愿者(三名男性,九名女性)进行同时闪烁显像和13C-辛酸呼气试验(13C-OABT)研究。胃的半空时间(t1 / 2)和滞后阶段(tlag)是测量和关联的两个主要GE参数。每10-15分钟使用NDIRS分析一次呼吸样本,共进行6小时,而前30分钟每分钟进行闪烁显像,然后每小时进行4小时。另外32名健康志愿者(19名男性,13名女性)仅接受13C-OABT来测量其固体GE。结果:在呼气试验和闪烁显像之间发现t1 / 2的显着相关性(r = 0.85,P = 0.001),而滞后时间也呈正相关(r = 0.73,P = 0.007)。基于所有44位受试者的t1 / 2B的参考范围是89.4-185.1分钟(135.9 +/- 21.1分钟(平均+/- SD)),而tlagB的参考范围是37.1-117.8分钟(81.9 +/- 17.4分钟) )。没有发现人口统计学特征影响GE参数。结论:NDIRS测定的13 C-辛酸呼气试验是一种简单,无创且可靠的测量方法,可提供一种“基于办公室”的工具来检测固体GE。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号