首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >Inter-session reliability and sex-related differences in hamstrings total reaction time, pre-motor time and motor time during eccentric isokinetic contractions in recreational athlete
【24h】

Inter-session reliability and sex-related differences in hamstrings total reaction time, pre-motor time and motor time during eccentric isokinetic contractions in recreational athlete

机译:休会期间可靠性和娱乐性运动员偏心等速收缩过程中绳肌总反应时间,运动前时间和运动时间的性别相关差异

获取原文
获取原文并翻译 | 示例
           

摘要

The purposes were twofold: (a) to ascertain the inter-session reliability of hamstrings total reaction time, pre-motor time and motor time; and (b) to examine sex-related differences in the hamstrings reaction times profile. Twenty-four men and 24 women completed the study. Biceps femoris and semitendinosus total reaction time, pre-motor time and motor time measured during eccentric isokinetic contractions were recorded on three different occasions. Inter-session reliability was examined through typical percentage error (CVTE), percentage change in the mean (CM) and intraclass correlations (ICC). For both biceps femoris and semitendinosus, total reaction time, pre-motor time and motor time measures demonstrated moderate inter-session reliability (CVTE< 10%; CM< 3%; ICC >0.7). The results also indicated that, although not statistically significant, women reported consistently longer hamstrings total reaction time (23.5 ms), pre-motor time (12.7 ms) and motor time (7.5 ms) values than men. Therefore, an observed change larger than 5%, 9% and 8% for total reaction time, pre-motor time and motor time respectively from baseline scores after performing a training program would indicate that a real change was likely. Furthermore, while not statistically significant, sex differences were noted in the hamstrings reaction time profile which may play a role in the greater incidence of ACL injuries in women.
机译:目的是双重的:(a)确定string绳肌的间歇性可靠性,包括总反应时间,运动前时间和运动时间; (b)检查ham绳肌反应时间的性别相关差异。 24名男性和24名女性完成了这项研究。在三种不同的情况下,记录了股二头肌和半腱肌的总反应时间,运动前时间和偏心等速收缩过程中的运动时间。通过典型的百分比误差(CVTE),均值变化百分比(CM)和组内相关性(ICC)检查会话间的可靠性。对于股二头肌和半腱肌,总反应时间,运动前时间和运动时间测量均显示中等的会话间可靠性(CVTE <10%; CM <3%; ICC> 0.7)。结果还表明,尽管统计学上无统计学意义,但女性报告的绳肌总反应时间(23.5 ms),运动前时间(12.7 ms)和运动时间(7.5 ms)值均持续高于男性。因此,在执行培训计划后,观察到的总反应时间,总运动时间,运动前时间和运动时间的变化分别比基线分数高出5%,9%和8%,这表明可能发生真正的变化。此外,尽管在统计学上不显着,但在绳肌反应时间曲线中注意到性别差异,这可能在女性ACL损伤发生率较高中起作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号