...
首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >Reproducibility of surface EMG variables and peak torque during three sets of ten dynamic contractions.
【24h】

Reproducibility of surface EMG variables and peak torque during three sets of ten dynamic contractions.

机译:在三组十次动态收缩中,表面肌电变量和峰值扭矩的重现性。

获取原文
获取原文并翻译 | 示例
           

摘要

The interpretation of the electromyogram (EMG) of dynamic contractions might be difficult because the movement per se introduces additional factors that could affect its characteristics. There is a lack of studies concerning the reproducibility of surface EMG registrations during dynamic contractions. The aim was to investigate the during-the-day reproducibility (using intra-class correlation; ICC) of the peak torque (PT) and the EMG variables (without removing the electrodes) of dynamic contractions. Ten healthy subjects performed three sets of 10 dynamic maximum right-knee extensions with a one-hour interval in between, using an isokinetic dynamometer and the PT was determined. EMG signals were recorded from the right vastus lateralis, rectus femoris and vastus medialis muscles using surface electrodes and the mean frequency of the power spectrum (MNF [Hz]) and the signal amplitude (RMS [microV]), were computed. The ability to relax in-between the maximum extensions was calculated as a ratio of the RMS during the passive flexion phase and the RMS during the active extension phase of each contraction cycle: the signal amplitude ratio (SAR). Both PT (ICC = 0.99) and RMS (ICC = 0.83-0.98) had good reproducibility. The reproducibility of MNF was good for all muscles when the mean of contraction nos.: 1-10 was used. Vastus lateralis had the highest ICC among the three muscles. The reproducibility of SAR was generally poor (ICC < 0.60). The present study showed good reproducibility for common EMG variables (MNF and RMS) obtained during maximum isokinetic contractions.
机译:动态收缩的肌电图(EMG)可能难以解释,因为运动本身会引入可能影响其特性的其他因素。缺乏有关动态收缩过程中表面肌电图配准的可重复性的研究。目的是研究动态收缩的峰值扭矩(PT)和EMG变量(不去除电极)的日间再现性(使用类内相关; ICC)。十名健康受试者使用等速测力计进行三组10次最大动态右膝伸肌训练,每组之间间隔1小时,并确定PT。使用表面电极记录右外侧外侧肌,股直肌和内侧内侧肌的EMG信号,并计算出功率谱的平均频率(MNF [Hz])和信号幅度(RMS [microV])。将最大伸展幅度之间的松弛能力计算为每个收缩周期的被动屈曲阶段的RMS与活动伸展阶段的RMS之比:信号幅度比(SAR)。 PT(ICC = 0.99)和RMS(ICC = 0.83-0.98)均具有良好的重现性。当使用平均收缩数:1-10时,MNF对所有肌肉的重现性都很好。在三块肌肉中,外侧腓肠的ICC最高。 SAR的再现性通常很差(ICC <0.60)。本研究显示出在最大等速收缩过程中获得的常见EMG变量(MNF和RMS)具有良好的重现性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号