首页> 外文期刊>Journal of Fuel Cell Science and Technology >Experimental Study on Performance of a Banded Structure Membrane Fuel Cell
【24h】

Experimental Study on Performance of a Banded Structure Membrane Fuel Cell

机译:带状结构膜燃料电池性能的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

The basic performance of a banded structure membrane fuel cell module (rated power of 90 W), which consisted of 15 polymer electrolyte membrane fuel cells laid out in a plane, was experimentally investigated. The results show that the module operated for a much longer time at an inclination angle, 6, of 90 deg than at 6 = 0 deg or 180 deg, where it experienced a sudden power breakdown at the rated operating point. The output voltage and internal impedance of each cell in the module were specifically monitored over a long-term operation. Measurements were made of the temperature distribution of the entire module as well as of the oxygen concentration and relative humidity at a specific cell. Airflow near the cathode in a single cell was also visualized. It was concluded that the power breakdown was probably caused by flooding in the anode of one of the most downstream cells of the module.
机译:实验研究了带状结构膜燃料电池模块(额定功率为90 W)的基本性能,该模块结构由15个平面布置的聚合物电解质膜燃料电池组成。结果表明,该模块在90°的6°倾斜角下的工作时间比在6 = 0度或180°下的工作时间长得多,在此情况下,模块在额定工作点突然断电。在长期运行中,专门监视了模块中每个单元的输出电压和内部阻抗。对整个模块的温度分布以及特定电池处的氧气浓度和相对湿度进行了测量。还可以观察到单个电池中阴极附近的气流。结论是,电源故障可能是由模块最下游电池之一的阳极中的溢流引起的。