首页> 外文期刊>Journal of glaucoma >Relationship between Humphrey 30-2 SITA Standard Test, Matrix 30-2 threshold test, and Heidelberg retina tomograph in ocular hypertensive and glaucoma patients.
【24h】

Relationship between Humphrey 30-2 SITA Standard Test, Matrix 30-2 threshold test, and Heidelberg retina tomograph in ocular hypertensive and glaucoma patients.

机译:眼部高血压和青光眼患者的Humphrey 30-2 SITA标准测试,Matrix 30-2阈值测试和Heidelberg视网膜断层扫描仪之间的关系。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate the relationship between global indices of Humphrey standard automated perimetry (SAP, 30-2 SITA standard test), Humphrey Matrix frequency doubling technology (FDT, 30-2 threshold test), and Heidelberg Retina Tomograph (HRT II) parameters and measure the level of agreement among these 3 tests in classifying eyes as normal or abnormal. METHODS: The study included 1 eye of 29 ocular hypertensive and 56 glaucoma patients with a mean age of 60.9+/-10.5 years. All subjects had reliable visual fields and HRT measurements performed within a 2-week period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA). Correlations between visual field indices (mean deviation and pattern standard deviation) and HRT parameters were analyzed using Spearman correlation coefficient (r) and the agreement between the tests in classifying eyes was defined with kappa value. RESULTS: FDT Matrix mean deviation and pattern standard deviation parameters were found to be highly correlated with those of SAP (r=0.66 and 0.69, respectively). Visual field indices showed statistically significant correlations with cup area, rim area, cup/disc (C/D) area, linear C/D, cup shape, mean retinal nerve fiber layer thickness and retinal nerve fiber layer area parameters (P<0.05). Fifty-eight patients (68.2%) had abnormal results at least with 1 of the tests and 21 subjects (24.7%) had abnormal results with all 3 tests. The kappa values were 0.6 for SAP and Matrix (P<0.001), 0.33 for SAP and MRA (P=0.002), and 0.31 for Matrix and MRA (P=0.004). CONCLUSIONS: FDT Matrix results are highly comparable with SAP in the assessment of glaucoma. Visual field global indices show statistically significant, but low-moderate correlations with most of the HRT parameters. The agreement among MRA and visual fields for abnormality is fair. Either HRT or visual fields may show the first evidence of glaucomatous damage; therefore, the combination of optic nerve head parameters andvisual field results could improve glaucoma diagnosis and follow-up.
机译:目的:评估汉弗莱标准自动视野检查(SAP,30-2 SITA标准测试),汉弗莱矩阵倍频技术(FDT,30-2阈值测试)和海德堡视网膜断层扫描仪(HRT II)参数的全球指标之间的关系,以及在将眼睛分类为正常还是异常时,测量这3种测试之间的一致性水平。方法:该研究包括29只眼的高血压和56例青光眼患者的1只眼,平均年龄为60.9 +/- 10.5岁。所有受试者均具有可靠的视野,并在2周内进行了HRT测量。根据视野标准和Moorfields回归分析(MRA)将眼睛分为正常/异常。使用Spearman相关系数(r)分析视野指数(平均偏差和模式标准偏差)与HRT参数之间的相关性,并用kappa值定义对眼睛进行分类的测试之间的一致性。结果:发现FDT矩阵平均偏差和模式标准偏差参数与SAP高度相关(分别为r = 0.66和0.69)。视野指数显示与杯面积,边缘面积,杯/盘(C / D)面积,线性C / D,杯形状,平均视网膜神经纤维层厚度和视网膜神经纤维层面积参数具有统计学意义的相关性(P <0.05) 。至少有一项测试有58名患者(68.2%)出现异常结果,而全部3项测试中有21名受试者(24.7%)都有异常结果。 SAP和Matrix的kappa值为0.6(P <0.001),SAP和MRA的kappa值为0.33(P = 0.002),Matrix和MRA的kappa值为0.31(P = 0.004)。结论:FDT Matrix结果在评估青光眼方面与SAP具有高度可比性。视野全局指数显示出与大多数HRT参数具有统计显着性但低度的相关性。 MRA和视野之间关于异常的协议是公平的。 HRT或视野都可能显示出青光眼损害的最初证据;因此,视神经头参数和视野结果的结合可以改善青光眼的诊断和随访。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号